9.1 GENERAL
Value measurements
Measurement
methods
Display
Polarity indication
Additional selectable
functions
Battery low charge
indication
Sampling frequency
Maximum opening of
jaws
Use
Storage
Power supply
Autonomy (when
measuring Volts DC)
Dimensions and
weight (with batteries)
Pollution level
Electrical safety
Delivered with the
instrument
9.2 REFERENCE CONDITIONS
Reference conditions: 18°C - 28°C; RH < 80 %, no
condensation
See table on page 42.
9. CHARACTERISTICS
CM600, CM610 & CM625: DC and
AC voltages, AC current,
resistance, continuity test
CM600 & CM610: diode test
CM625: DC current
CM610 & CM625 :True RMS AC
(true effective voltage)
CM600 & CM610: 2000 points
CM625: 4369 points
" – " sign
Automatic range selection
Automatic shutdown (active or not)
Display of capacity being
exceeded
CM600 & CM610: maximum
measurement (Max Hold)
CM625: measurement storage
(Data Hold)
Low battery symbol
CM600 & CM610: approx. 3 x per
sec.
CM625: approx. twice per sec.
30 mm
0 to 50°C (32°F - 122°F). RH <
80%, no condensation
-10°C to 60°C (14 - 140°F); RH <
70%, no condensation and with the
battery removed
2* 1.5V LR3 type batteries (AAA)
CM600 & CM610: 400 hours
(alkaline battery) or 200 hours
(standard battery)
CM625: 100 hours (alkaline
battery)
189 x 71 x 37mm (L x W x H)
CM600 & CM610: 200 g
CM625: 220 g
2
IEC 61010-1 – IEC 61010-2-032 –
IEC 61010-2-033
300 V CAT III
2* 1.5V AAA / LR3 type batteries
2 power cables
1 set of operating instructions
1 protective device
17