25 6.1 Suggested Lubricants; 25 6.2 Cleaning And Servicing; 25 6.2.1 Service Intervals; 26 6.2.3 Gearbox Oil Change - Bosch TCE 5330 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 64
en
40 | TCE 5330 | Maintenance
6.
Maintenance
6.1
Suggested lubricants
Component
Lubricant
Gearbox
ESSO Spartan EP460 ISO 460
Hydraulic pump
ESSO NUTO H 46
Pneumatic sys-
ESSO FEBIS K 32
tem (conditio-
ning assembly)
Tab. 1:
Lubricants table.
!
The manufacturer is not liable for any damage
caused by use of lubes different from those shown in
the table.
6.2
Cleaning and servicing
Before any cleaning or maintenance interven-
tion, disconnect the TCE 5330 by means of
the main switch and disconnect the network.
To guarantee full efficiency of the TCE 5330 and to
ensure functioning without anomalies it is essential to
clean the machine regularly and carry out periodical
maintenance.
Maintenance has to be carried out by the operator
in accordance with the manufacturer's prescriptions
shown here below.
6.2.1
Service intervals
Maintenance
Charge completely the remote control battery.
Clean the mechanical moving parts,
spray them with nebulized oil or kerose-
ne and lube with appropriate grease
Remove condensate.
Check oil level in the oil nebulizer.
Check transmission belt tensio-
ning in order to avoid its sliding.
Check the oil level of the hydrau-
lic control unit and keep it always bet-
ween minimum and maximum
Check and maintain the grease level on the
self-centering and on the tool holding arm.
Lubricate with grease the sli-
ding rail of the trolley.

Change oil in the oil nebulizer.

|
1 695 301 841
2010-02-16
Maintenance
Standard
Change the oil in the hydraulic control unit.
Check the gearbox oil level.
DIN 51502-CLP
ISO 34-98-CC
ISO 46
6.2.2
DIN 51502-HLP
1. Power off the equipment;
DIN 51524 PART.2-
2. Unscrew the cap with measuring rod on the hydrau-
HLP
ISO 67-43-HM
ISO VG 32
3. Check that the oil level is between MIN and MAX.
6.2.3
1. Put a container underneath the gearbox.
2. Unscrew the microswitch under the tool holding
3. Unscrew the oil discharge screw.
4. Discharge oil in the gearbox and dispose it (see
5. Unscrew the microswitch under the tool holding
6. Top up with new gearbox oil (see lube table).
7. Screw the oil discharge screw.
6.2.4
1. Turn left the red button placed in the lower part of
2. Remove the accumulated condensate.
3. Turn back in previous position the red button placed
6.2.5
1. Disconnect pneumatic connection.
2. Unscrew the tank cap on the oil nebulizer.
3. Top up oil (see lube table).
x
x
x
x
x
x
6.2.6
x
1. Disconnect pneumatic connection.
2. Unscrew the tank cap on the oil nebulizer.
x
3. Discharge oil and dispose it (see chap. 7.3).
x
4. Top up with new oil (see lubricant table).
Check the hydraulic control unit oil level
lic control unit.
Gearbox oil change
arm;
chap. 7.3).
arm;
Condensate removal
the water separator.
in the lower part of the water separator.
Nebulizer oil refill
Change oil in the oil nebulizer
x
x
Robert Bosch GmbH

Publicidad

Tabla de contenido
loading

Tabla de contenido