Operation; Lighting Instructions - Desa VN20BTB Información Seguridad Y Manual De Instalación

Calentador de gas de llama azul no ventilado sin ventilas
Ocultar thumbs Ver también para VN20BTB:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INsTallaTIoN
Continued
3. Make sure control knob of heater is in the
OFF position.
4. Check all joints from equipment shutoff
valve to thermostat gas valve (see Figure
17 or 18). Apply a noncorrosive leak de-
tection fluid to all joints. Bubbles forming
show a leak.
5. Correct all leaks at once.
6. Light heater (see Operation). Check all
other internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to
Appliance, page 15).
8. Replace front panel.

oPeRaTIoN

FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must
be lighted by hand. When lighting the pi-
lot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the floor because some
gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn by
hand, don't try to repair it, call a qualified
service technician. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part
has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part of
the control system and any gas control
which has been under water.
14
1. STOP! Read the safety information, col-
umn 1.
2. Make sure equipment shutoff valve is fully
open.
3. Turn off any electric power to the appli-
ance if service is to be performed.
4. Turn control knob clockwise
OFF position.
5. Wait five minutes to clear out any gas.
Then smell for gas, including near the
floor. If you smell gas, STOP! Follow "B"
in the safety information, column 1. If you
don't smell gas, go to the next step.
6. Turn control knob counterclockwise
to the PILOT position. Press in control knob
for five (5) seconds.
7. With control knob pressed in, push down
and release ignitor button. This will light
pilot. The pilot is attached to the front of
burner. Note: You may be running this
heater for the first time after hooking up to
gas supply. If so, you may need to press in
control knob for 30 seconds or more. This
will allow air to bleed from the gas system.
If needed, keep pressing ignitor button until
pilot lights. If ignitor does not light pilot, re-
fer to Troubleshooting, page 17 or contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 15.
8. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
Ignitor Button
Figure 19 - Control Knob In The OFF
Thermocouple
Figure 20 - Pilot (actual pilot may vary)
www.desatech.com
LIGHTING
INSTRUCTIONS
Control Knob
Position
Ignitor Electrode
to the
Pilot Burner
121880-01B

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Vp20btbVn30btbVp30btb

Tabla de contenido