8.2 Operation methods same as Chapter 6
8.3 Stopping the Unit
8.3.1 For emergency
Directly turn the ignition switch key to OFF position.
8.3.2 For normal condition
8.3.2.1 Turn off the AC breaker and unplug all the loads
8.3.2.2 Run the unit for several minutes without load to cool down the generator
set.
8.3.2.3 Set the ignition switch to OFF position
8.3.2.4 Set the fuel switch to OFF position
8.4 Replacement of the Battery
If your unit can be started by recoil start, but cannot be started by electrical start,
please run the unit with recoil start and have your battery charged for 20 minutes.
If the unit still cannot be started by electrical start, please have the battery
replaced as follows.
8.4.1 Disconnect the positive and negative poles of the battery with wires.
8.4.2 Remove the battery hold-down plate.
8.4.3 Install a new battery and the hold-down plate.
8.4.4 Connect the relevant wires with the positive and negative poles.

9. Storage and Transportation

Turn off fuel switch and ignition switch to avoid fuel leakage during transportation.
Gasoline vapor and leakage can be easily ignited.
WARNING Allow the unit to cool down before storage and/or
transportation so as to prevent burns resulting from accidentally touching
the hot surfaces of the engine. Take care to avoid the unit from falling
down during transportation. Don't place heavy objects on the unit.
9.1 When storing the unit for long time pay attention to the following:
9.1.1 The storing places should be dry and clean
9.1.2 Carry out maintenance according to the table below:
21