Smart functions:
-Auto Shut Off
When the bucket full indicator light illiminates and the setting humidity is reached, the unit will be shut off
automatically.
-Wait 3 minutes before resuming operation After the unit has stopped, it can not be restart opertation in the
first 3 minutes. This is to protect the unit. Operation will automatically start after 3 minutes.
-Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until
the frost disappears.

-Auto-Restart

If the unit breaks off unexpectedly due to the power cut, it will restart with the previous function setting
automatically when the power resumes.
NOTE:
All the illustrations in the manual are for explanation purpose only. Your machine may be slightly different.
The actual shape shall prevail. The design and specifications are subject to change without prior notice for
product improvement. Consult with the sales agency or manufacturer for details.
NOTE:
The control panel of the unit you purchased may be look like one of the followings:
Auto defrost
PUMP button(optional)
Press to activate the pump operation.
NOTE: Make sure the pump drain hose is installed into the unit and the continuous drain hose is removed
from the unit before the pump operation is activated. When the bucket is full, the pump starts to work.
Refer to the next pages for removing the collected water. Do not use this operation when the outdoor
temperature is equel to or less than 0ºC (32ºF).
Full
On
Off
Full
Defrost
20
DEHUMIDIFIER
TDH030110MD
On
Off