MEASURING AUDIBLE CONTINUITY
1.- Connect the red testing point in the jack signaled "VΩmA"
and the black testing point in the jack signaled "COM".
2.- Set the dial to the ")))" range.
3.- Connect the testing points on the circuit to be measured. If
the resistance is less than 30Ohms the multimeter will beep.

BATTERY REPLACEMENT

1.- Unscrew the battery compartment´s cover and remove.
2.- Insert a 9V - - - battery, pay attention to polarity
3.- Place again the cover and screw.