Switching On The System - Waeco DC-Kit3 Instrucciones De Montaje Y De Uso

Set de ampliación para cc
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
DC-Kit3.book Seite 32 Freitag, 13. Juni 2008 3:24 15
Using the DC kit
e
Caution!
CA2500, B2200: the inverter may be damaged.
If you are operating the system on the 230 V mains and the auto-
matic air conditioner or the heating is on, make sure that the invert-
er is switched off and stays switched off.
The inverter is not designed for the amount of power an active heat-
ing system requires. If the 230 V mains power fails, the inverter
would then take over supplying the power.
8.1

Switching on the system

Observe the following instructions before you switch on the system:
Air the vehicle.
Make sure that the ventilation slots on the air nozzles and the fan of the
components are not covered up.
Make sure that all the housings and cables are not damaged and that all
the insulation is intact.
Compare the existing supply voltage with the technical data.
Do not insert any fingers or objects into component openings.
I
Note
CA2500, B2200: the remote control for the roof air conditioner can
only be used if the air conditioning is supplied with 230 V mains net-
work or with the inverter.
Stationary mode: 230 V~ mains operation
The system is supplied with 230 V~ from the mains. Leave the inverter
switched off.
The VS-230-2 priority circuit is supplied with power and supplies the second
socket with power for any connected consumer units.