Waeco DC-Kit3 Instrucciones De Montaje Y De Uso página 33

Set de ampliación para cc
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
DC-Kit3.book Seite 33 Freitag, 13. Juni 2008 3:24 15
DC-Kit3
Driving mode: power supply from the 12 V battery
➤ Switch on the inverter using the MCR9 remote control.
e
Caution!
CA2500, B2200, HB2500: the inverter may be damaged.
Do not switch on the roof air conditioner in the automatic or heating
modes.
➤ Use the roof air conditioner as described in the operating manual.
The roof air conditioner is switched off: the priority circuit supplies voltage
to both sockets.
The roof air conditioner is switched on: the priority circuit switches the sec-
ond socket off so that the inverter does not overload as a result of additional
consumer units when operating the roof air conditioner.
Driving mode: power supply from the 12 V battery with motor switched
off.
CA1000, CA2500, B2200
If the inverter switches off due to low voltage in the supply battery
(10.5 V), no voltage will be supplied to the socket and the roof air
conditioner switches off. The inverter is in standby mode.
As soon as the power from the supply battery reaches the inverter's
activation point, the socket is supplied with voltage again.
You have to switch on the roof air conditioner again manually, as the
control electronics need to be reactivated after a lack of voltage.
B1600, HB2500
If the inverter switches off due to low voltage in the supply battery
(10.5 V), no voltage will be supplied to the socket and the roof air
conditioner switches off. The inverter is in standby mode.
As soon as the power from the supply battery reaches the inverter's
activation point, the socket is supplied with voltage again.
The roof air conditioner starts automatically.
Using the DC kit
33

Publicidad

Tabla de contenido
loading

Tabla de contenido