1) Check the space between the mobile door and column, and between the door and floor, and ensure that no obstacles are
present before switching on the system.
2) Switch on the system by means of the thermal cutout switch pushbutton. With the door in the mid-travel position, after waiting
approx. ten seconds the door should open. However if it closes, switch off the system and move the microswitch on the side to
the control panel near the red/green leds to the side of the 9-core connector (fig. 5) and switch on the system again.
3) Move the door manually to ensure there is no friction.
4) Ensure correct activation of the sensors.
5) Adjust the Trimmers according to your requirements:
a - Pause time before automatic closing is completed (0.5sÖ10s)
b - Adjustment of opening speed
c - Adjustment of closing speed
d - Adjustment of speed during the slow opening and closing phase
6) Attach adhesive labels indicating that the door is automatic and fit the front cover (optional).
7) Give the door manual to the user.
Fig6
Fig7
Fig.8
FINAL CHECKS
VOLTAGE
COMMAND
ON - RH
a
TEST - LH
OPENING SPEED
AUTOMATIC CLOSING TIME
Fig.9
Fig.10
®
+
+
+
+
c
d
b
CLOSING SPEED
LOW SPEED
Pag. 31 di 44