Service And Repairs - Metabo HPT EC 99S Manual De Instrucciones Y Instrucciones De Seguridad

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2.
Draining tank
Drain tank daily or after 4 hours of use. Open drain cock
and tilt compressor to empty accumulated water (Refer to
Fig. 8).
3.
Oil change-oil topping off
CAUTION: Overfi lling with oil will cause premature
compressor failure. Do not overfi ll.
(1) Within the fi rst 50 hours of operation, completely replace
the oil of the pumping element. Unfasten the oil drain cap
on the carter cover, drain all the oil, and screw the cap
back on (Refer to Fig. 1 and to Fig. 10)
Drain cap
Fig. 10
4.
Maintenance chart:
PROCEDURE
Check pump oil level
Oil leak inspection
Drain condensation in air tanks
Inspect guards/covers
Check for unusual noise/vibration
Check for air leaks
Clean exterior of compressor
Inspect fi lter
Check safety valve
Change pump oil
Replace fi lter

SERVICE AND REPAIRS

All
quality
compressors
servicing
or
replacement
and
tear
from
normal
genuine replacement parts will be used, all service
and repairs must be performed by a metabo HPT
AUTHORIZED SERVICE CENTER, only.
NOTE: Specifi cations are subject to change without any
obligation on the part of the metabo HPT.
MAINTENANCE CHART
AFTER USE
×
will
eventually
require
of
parts
because
of
wear
use.
To
assure
that
only
— 13 —
Pour oil into the hole of the dipstick.
To the level indicated on the dipstick (Refer to Fig.5).
For oil replacement, follow the table below.
OIL TYPE
SAE 5W50 SYNTHETIC OIL (-20° +120°F)
For both summer and winter use
SAE 15W40 MULTI-GRADED OIL (+5° +104°F)
For warm weather use only
(2) Check the oil level of the pumping elemt every 50
hours or once a week.
(3) Change the oil every 300 working hours or every 6
months
DAILY
WEEKLY
×
×
×
×
×
×
×
×
×
English
300 HOURS
×
×

Publicidad

Tabla de contenido
loading

Tabla de contenido