Installation; Terminals And Connection Diagram - Fermax FPAC-MAX Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Cod. 970077b V04_21
Table 1. Specification
Maximum
number
fingerprint templates
Fingerprint
modes
Proximity cards
Supply voltage
Avg. current consumption
Inputs
Ethernet
Port RS485
Tamper
Environmental
(according to EN 50131-1)
IP grade
Dimensions H x W x D
Weight
Certificates
3. I
NSTALLATION

3.1 Terminals and connection diagram

1900
of
1:N mode – fingerprint templates are recorded in reader memory
identification
1:1 mode – fingerprint templates are recorded on Mifare cards
Mifare Classic
Nominal 12Vdc, min./max. range 10-15Vdc
130 mA for 12Vdc
Two NO inputs (IN1,IN2), electrically biased to +12Vdc via 15kΩ
resistor, triggering level approx. 3.5Vdc
10BASE-T 10/100Mb Ethernet communication port
RS485 communication port
Isolated contact, NC type, 24Vdc/50 mA rated
Class I, indoor general conditions, temperature: +5°C to +40°C,
class
relative humidity: 10 to 95% (no condensation)
IP41
85mm x 85mm x 52mm
160g
CE
Fig. 2 FPAC-MAX FINGERPRINT terminals
FPAC-MAX
4 | 16

Publicidad

Tabla de contenido
loading

Tabla de contenido