Filter replacement
Do not spread dust during dust bag replacement!
- Wear adequate filter mask;
- S 145EM – S 145EPM: seal the dust container with the
appropriate cap (33);
- detach the head pushing the side hooks (11) (pic.7-8);
- turn the head upside down (pic.15);
- remove the filter frame (21) turning the hooks (22) (pic. 16);
- remove the filter cartdridges (pic. 17) and fit them into a
sealed disposal bag;
- fit new filter (cod. 036.1108) cartridges in the filter frame
reassemble it on the head.
(pic.18) and
Use genuine RUPES spare parts only.
Refer to www.rupes.com for parts code and authorized
service centre
RUPES Spa. will not be held responsible for direct or indirect
damages resulting from non-compliance with the requirements
of this manual.
TROUBLESHOOTING AND SOLUTION
EFFECTS
The motor will not start
The vacuum does
not start automatically
Vacuum flow is insufficient
Dust from the exhaust (10)
Tools do not start
Insufficient Power for pneumatic tool
Red indicator on
Yellow indicator on
TOOL IDENTIFICATION PLATE
POSITION AND MEANING OF INFORMATION
1. Type of tool.
2. Nominal working voltage Volts (V).
3. Working frequency Hertz (Hz).
4. Class of protection.
5. Absorbed power Watt (W).
6. Power at socket (MAX) Watt (W).
7. Power max Watt (W).
8. Serial number.
9.
and save these instructions.
10.
European Directive 2002/96/CE (RAEE) + 2003/108/CE and
its implementation in national law, must not be released into
the environment or thrown away as domestic waste, but must
be disposed of at authorised recycling centres (contact the
relevant local authorities for a list of places where the product
may be disposed of according to the law).Disposing of the
product correctly contributes to protecting human health and
safeguarding the environment. Any illegitimate disposal of the
product will be punishable by law.
CAUSES
No power
Power cord, switch or
motor defective
Electronic module
Bag full
One of the hoses or
accessories is clogged
Clogged filters
Filter cartridge torn ripped
3-way switch malfunction
Insufficient compressed air feeding
Ordinary maintenance limit exceeded
Max. liquid level exceeded
Read all this instructions before operating this product
At the end of its useful life, the product, pursuant to
SOLUTIONS
Make sure the unit is plugged in
Contact an authorised service centre
Contact an authorised service centre
Check the filter bag
Check the flexible hose and the
accessories
Check the filters cartridges
Contact an authorised service centre
Contact an authorised service centre
Check air passage
Contact an authorised service centre
Empty the bin