Technical Data; Scope Of Delivery - DIPRA SPIDO ECC PRO 500 Manual De Instrucciones Original

Bomba de evacuación
Ocultar thumbs Ver también para SPIDO ECC PRO 500:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32

3. TECHNICAL DATA

Model
Mains voltage / frequency
(V / Hz)
Nominal performance (Watts)
Protection type (IP)
Pressure port
Max. flow rate (Qmax)
(l/h)
(1)
Max. pressure (bar)
Max. delivery height
(Hmax)
(m)
(1)
Max. submersion depth (m)
Max. size of the solids being
pumped (mm)
(suspended feces)
Max. fluid temperature
(Tmax) (°C)
Min. fluid temperature (°C)
Length of connection
cable(m)
Cable type
Weight (net) (kg)
Dimensions (L x D x H) (mm)
1) The values were determined with free, unreduced outlet.

4. SCOPE OF DELIVERY

The scope of the delivery of this product includes :
One pump with connection cable, one connection
port, one operating manual.
Please verify that the scope of delivery is complete.
Depending on the purpose of the application, addi-
tional accessories may be necessary (please refer to
the chapters titled "Installation" and "How to order
spare parts").
If possible, keep the packing until the warranty peri-
od has expired. Please dispose of the packing mate-
rials in an environmental-friendly manner.
5. INSTALLATION
5.1. GENERAL INSTALLATION INFORMATION
MAXINOX 700
230 / 50
700
68
M1"1/2 (40/49)
18 000
All connection lines have to be perfectly tight since
0,8
leaking lines may affect the performance of the
pump and cause considerable damage. If required,
8
please use a suitable sealant to make the installation
airtight.
7
When tightening threaded connections, please do
30
not apply excessive force which may cause damage.
When laying the connection pipes, you should
make sure that the pump is not exposed to any
35
form of weight, vibration or tension. Moreover, the
5
connection lines must not contain any kinks or an
adverse slope.
10
Please observe the illustrations.
H07RN-F
5.2. INSTALLATION OF THE PRESSURE LINE
7
The pressure line conveys the liquids to be discharged
195 x 164 x 366
from the pump to the point of withdrawal. To avoid
dynamic flow losses, one should use a pressure line
having at least the same diameter as the pressure
port of the pump.
1. Screw the fitting into the pump outlet.
2. Attach a pipe to the end cap.
Use the largest hose diameter possible.
5.3. STATIONARY INSTALLATION
If the unit is used in a stationary installation, rigid pipes
have proven to be the ideal choice for the pressure
lines. In this type of installation, we recommend that
you incorporate a check valve (non-return valve) in
the pressure line immediately following the pump
outlet so that no liquid will flow back after the pump
cuts out. To facilitate maintenance work, we also
recommend the installation of a stop cock valve
downstream of the pump and check valve. This
arrangement is beneficial in that closing the stop
cock will prevent the pressure line from running dry
after the disassembly of the pump.
During the entire process of installation, the
device must not be connected to the
electrical mains.
The pump and the entire connection
system have to be protected from frost.
GB

Publicidad

Tabla de contenido
loading

Tabla de contenido