3. TECHNICAL DATA
Model
Mains voltage / Frequency
(V / Hz)
Nominal performance (Watts)
Protection type (IP)
Suction port
Pressure port
Max. pressure (bar)
Max. flow rate (Qmax)
(l/h)
(1)
Max. size of the solids being
pumped (mm)
Min. fluid temperature (°C)
Max. fluid temperature
(Tmax) (°C)
Length of connection cable (m)
Weight (net) (kg)
Dimensions (L x D x H) (mm)
1) The values were determined with free, unreduced in- an
outlet.
2) Noise emission values obtained according to the EN 12639
regulation. Measurement method according to EN ISO
3744.
4. SCOPE OF DELIVERY
The product comes with the following items: a
pump, a transformer, a power cable and instructions
for use.
Please verify that the scope of delivery is complete.
Depending on the purpose of the application,
additional accessories may be necessary (please
refer to the chapters titled "Installation".)
If possible, keep the packing until the warranty
period has expired. Please dispose of the packing
materials in an environmental-friendly manner.
5. INSTALLATION
5.1. GENERAL INSTALLATION INFORMATION
BOOSTER PUMP
Pump : 12V DC
Transformer :
230V AC - 12V DC
45
X4
and the entire connection system have to be
protected from frost and other climatic influences.
M15/21 (1/2")
M15/21 (1/2")
7,5
230
0
5.2. PREPARATION FOR INSTALLATION
5
The aim of the installation is to provide a quiet and
35
easy to maintain product with good flow and high
pressure. This can be achieved with the following
1,2
guidelines:
0,680
- Mount the installation on a flat and accessible
surface for cleaning the strainer and servicing the
165 x 100 x 60
pump.
- Use a high pressure hose on the inlet and outlet
of the pump. The pump ports and strainer must not
be connected to a rigid hose. Otherwise the normal
movement of the pump will be transmitted through a
rigid hose causing noise and possibly loosening or
cracking components.
- The pump should ideally be used with a 400 micron
(40 mesh) pre-filter.
- Use a hose with a minimum of 9 mm (3/8 inch)
inside diameter. A smaller hose size may result in
high back pressure, low flow and noise.
- The pump is designed for intermittent service only.
Coupling to a timer is recommended.
- Do not use this pump to operate a reverse osmosis
filtration system. Continuous use at high pressure
will shorten the life of the pump and is not covered
by the warranty.
- If an extension cable is used, keep only the original
section.
- The electrical circuit must be protected by a
minimum 10A circuit breaker.
- Do not reduce the inlet and outlet diameters.
This includes small inside diameter shut-off valves,
winterizing valves and elbows.
- For potable water only
- Residential installation in private homes. Cannot be
used in a public facility.
During the entire process of installation, the
device must not be connected to the
electrical mains.
The pump should be installed in a dry place
with an ambient temperature not to exceed
40 °C and not to fall below 5 °C. The pump
When installing the device, please make
sure that the motor is sufficiently ventilated.
GB