Inspect the muffler and the spark arrester (if equipped)
every 50 hours. If muffler is equipped with a spark arrester
screen, remove the screen for inspection. Replace the
screen if damaged or plugged. If inspection determines that
replacement parts are required, make sure to use only
original equipment replacement parts.
Fire could result.
• Replacement parts must be the same and installed in
the same position as the original parts.
How To Change The Oil
Remove Oil
1. With engine off but still warm, disconnect the spark plug
wire (A) and keep it away from the spark plug (Figure 8).
Figure 8: Spark Plug
2. If you drain the oil from the top of the engine through the
engine oil fill (B), make sure to keep the spark plug side
(C) up (Figure 9). Drain the oil into an appropriate
receptacle.
C
B
Figure 9: Drain Oil
10
WARNING
A
3. If you drain the oil from the bottom of the engine, remove
the oil drain plug (D) as shown in Figure 10. Drain the oil
into an appropriate receptacle.
Note: Some of the various types of oil drain plugs (D)
are shown in Figure 10.
Figure 10: Oil Drain Plugs
4. Replace and tighten the oil drain plug.
Before adding oil
• Place engine level.
• Clean the oil fill area of any debris.
Extended Dipstick
1. Remove the dipstick (B) and wipe with a clean cloth
(Figure 11).
2. Pour the oil slowly into the engine oil fill (D). DO NOT
OVERFILL. After adding oil, wait one minute and then
recheck the oil level.
3. Insert and tighten the dipstick.
4. Remove the dipstick and check the oil level. Make sure
the oil is at the FULL mark (C) on the dipstick.
5. Replace and tighten the dipstick.
B
D
Figure 11: Extended Dipstick
D
B