Operating instructions SATA filter 400
• Slide condensate drain hose [1-10] over the drain valve [1-9]; put hose
end into a suitable collection container (not included in delivery).
Notice!
• Mount shut-off tap in front of the filter, e.g. Art. No. 10934 (not in-
cluded in delivery), allowing easy and safe filter maintenance.
7.2. Retrofit SATA filter 444 to filter 484 [2]
For retrofitting with an activated charcoal filter, a SATA filter 464 [C] (Art.
No. 141473) is required:
1. Depressurise filter (close shut-off tap)
2. Loosen [2-1] air outlet module [D] from the dual-stage filter combina-
tion [A]/[B]
3. Complete SATA filter 464 by glueing in the threaded connection piece
[E] the insert [F] and the sleeve nut [G]
4. Screw on [2-2] SATA filter 464 [C]
5. Screw on [2-3] air outlet module [D]
8.
Use
Use solvent-resistant, antistatic, undamaged, technically flawless com-
pressed air hoses with a continuous pressure resistance of minimum 10
bar, e.g. Art. No. 53090!
Notice!
• Mount compressed air connector ¼" (internal thread) or matching
SATA-quick-action coupling G ¼" (internal thread) (item no. 13599,
not included in delivery) on the ball tap [1-6].
• For regular filter maintenance, replace and activate the SATA filter
timer of the respective filter stage (sintered filters and fine filters every
6 months, activated carbon filters every 3 months).
6. Connect suitable compressed air hose.
7. Turn the pressure adjustment knob [1-5] in counterclockwise direction
to the maximum; state = closed
Warning! Attention!
EN