2)
MENU
Click "SETUP" to configure the connected zoom lens control camera.
Different zoom lens control cameras might have different parameter settings. For details, please refer to their
own user manuals.
Note: While configuring the camera parameters, the DVR will switch to the corresponding channel, and
you can simultaneously preview the effects for the settings.
3)
DEVICE
Here shows the model number of the camera.
4)
CONNECTION
Here shows the examining result for DCCS signal transmission between the DVR and camera. The
message is as follows:
MESSAGE SHOWN
CHECKING
OK
FAIL
5.5.10 IVS
IVS, Intelligent Video Surveillance, is the advanced application for motion detection, but more precise and smarter.
It can be applied to different situations with one of the following three modes: FLOW COUNTING, VIRTUAL
FENCE, and ONE WAY PASS.
When anyone crosses the detection line (virtual fence), the recording will be on.
CANERA
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11
DETECTION
ALERT
NETWORK
SNTP
DISPLAY
RECORD
REMOTE
DCCS
IVS
EXIT
1)
IVS FUNCTION
Select to enable or disable IVS function (ON / OFF).
2)
IVS MODE
Select one of the following three modes depending on your environment:
MODE
FLOW COUNTING
VIRTUAL FENCE
ONE WAY PASS
3)
DISPLAY LINE
Select to display the detection line for IVS on the screen or not.
4)
SENSITIVITY
Set the sensitivity for IVS from 00 ~ 15. The larger the value, the more sensitive the IVS will be.
MEANING
The DVR is checking the DCCS signal transmission between the DVR and camera.
The signal transmission is fine and the DCCS function works properly.
The signal transmission is too weak or not available for the DCCS function to work properly.
ADVANCE CONFIG
IVS FUNCTION
IVS MODE
DISPLAY LINE
SENSITIVITY
RESET COUNT
VIRTUAL FENCE AREA
DESCRIPTION
A virtual detection line is set to detect the moving direction of pedestrians for flow counting.
A virtual detection line is set to detect intruders crossing the detection line, and an alarm will be
triggered.
A virtual detection line is set to detect intruders from the specified direction, and an alarm will be
triggered.
ON
FLOW COUNTING
OFF
07
SUBMIT
SETUP
27
MAIN MENU