For Set delay, specify an interval (in ms) during which the setpoint
must be continually met. An electrical signal change is then carried out
after this delay is met.
5
For Reset delay, specify an interval (in ms) during which the reset
point must be continually met. An electrical signal change is then car-
ried out after this delay is met.
6
For the Mode selection, choose the desired switch function for the
pressure switch. Some practical examples for the available modes are
shown below.
Available switching function in the Mode drop-down box
Hysteresis function, NO contact
In this mode, the output switches
on when the setpoint is reached
and switches off when the reset
point is reached.
60
Hysteresis function, NC contact
In this mode, the output switches
off when the setpoint is reached
and switches on when the reset
point is reached.