20.
With (2) people lifting table, carefully return it to upright
position. To verify proper table operation, do the following:
a. To fold table into vertical position, push front edge of
worksurface down while pulling control levers to unlock.
b. Lift worksurface up.
c. To unfold table into horizontal position, pull control
levers to unlock (you may need to shake table to work
locking pins out of holes), and pull down worksurface.
d. Push down on front edge of worksurface to lock.
Repeat steps 20a to 20c two more times to ensure that
table functions properly.
21.
Perform the following final check:
a. While table is in user position (horizontal), push down
on rear of table carefully to make sure table is locked.
b. If table unlocks, review this document to ensure that
all steps were followed. Contact Steelcase immediately
if troubleshooting effort fails.
21a
FRONT
REAR
20a
20c
20b
20d
FRONT
Page 8 of 24
1051162001 Rev G