Technical Data

Pressure washer
Article number
Rated power
Supply temperature max.
Supply rate min.
l/min
Rated pressure
Max. operating pressure
Rated Flow
l/min
Maximum inlet pressure
Kickback force at the gun to the
maximum pressure
Motor insulation
Motor protection
Detergent tank
Autostop function
Net impedance
Weight according to EPTA-
Procedure 01:2014
Protection class
Serial number
See serial number (rating
The values given are valid for a nominal voltage [U] of 230 V. For differ-
ent voltages and models for specific countries, these values can vary.
Starting cycles generate brief voltage drops. Interference with other
equipment/machines may occur in case of unfavourable mains system
conditions. Malfunctions are not to be expected for system impedances
below 0.358 ohm.

Noise/Vibration Information

Sound emission values determined according to
EN 60335-2-79.
Typically the A-weighted noise levels of the product are:
Sound pressure level 81.8 dB(A); sound power level
90 dB(A). Uncertainty K =3 dB.
Wear hearing protection!
Vibration total values a
(triax vector sum) and uncertainty K
h
determined according to EN 60335-2-79:
2
2
a
=3.12 m/s
, K=1.5 m/s
.
h

Mounting and Operation

Action
Delivery Scope
Insert dip stick for ventilation
Connect detergent bottle
Connecting to the water supply
Clean the water filter
Connecting high pressure water supply
hose/nozzle
Bosch Power Tools
Action
Adjust water pressure
GHP 5-13 C
Adjust water jet
3 600 J10 0..
Switching On and Off
kW
2.3
Working Advice
°C
50
Clean nozzle
8.3
MPa
13
Starting
MPa
14
For Your Safety
8.3
MPa
1
N
22.11
Class F
Your machine is double insulated for safety and requires no
earth connection. The operating voltage is 230 V AC, 50 Hz
IPX5
(for non-EU countries 220 V, 240 V as applicable).
For increased electrical safety use a Residual Current Device
(RCD) with a tripping current of not more than 30 mA. Always
0.358
check your RCD every time you use it.
The supply cables must be inspected for signs of damage at
kg
16.5
regular intervals and may only be used if in perfect condition.
/I
If the replacement of the supply cord is necessary, this has to
be done by Bosch or an authorized Bosch service agent in or-
plate) on pressure
der to avoid a safety hazard.
washer.
Only use approved extension cables.
Extension cords, cables, leads, reels should only be used if
they comply with EN 61242/IEC 61242 or
IEC 60884-2-7.
If you want to use an extension cable when operating your
product, only the following cable dimensions should be used:
– Nominal Conductor Area of 1.5 mm
of 20 m for a Cord Extension Set
The connections (plugs and sockets) should be kept dry and
off the ground.
It is recommended that this is accomplished by means of a
cord reel which keeps the socket at least 60 mm above the
ground.
Note: If an extension cable is used it must be earthed and con-
nected through the plug to the earth cable of your supply net-
work in accordance with prescribed safety regulations.
Figure
Page
Refer to the instruction manual of the extension cord, lead,
reel manufacturer and your local wiring regulations.
1
234
If in doubt contact a qualified electrician or the nearest Bosch
2
234
Service Centre.
3
235
For products not sold in GB:
4
235
WARNING: For your safety, it is required that the plug at-
5
235
tached to the product is connected with the extension cord.
The coupling of the extension cord must be protected against
6
236
splash water, be made of rubber or coated with rubber. The
extension cord must be used with a cable strain relief.
Autogoods "130"
English | 15
Figure
7
8
9
10
11
Warning! Switch off, remove plug from mains
before adjusting, cleaning or if cable is cut,
damaged or entangled.
WARNING! Inadequate extension cables can
be dangerous. Extension cable, plug and sock-
et must be of watertight construction and in-
tended for outdoor use.
2
to a max. cable length
1 609 92A 3EP | (14.7.17)