OBJ_BUCH-1762-003.book Page 15 Wednesday, July 12, 2017 2:29 PM

Technical Data

Pressure washer
Article number
Rated power
Supply temperature max.
Supply rate min.
Rated pressure
Max. operating pressure
Rated Flow
Maximum inlet pressure
Kickback force at the gun to the maximum pressure
Motor insulation
Motor protection
Detergent tank
Autostop function
Net impedance
Weight according to EPTA-Procedure 01:2014
Protection class
Serial number
The values given are valid for a nominal voltage [U] of 230 V. For different voltages and models for specific countries, these values can vary.
Starting cycles generate brief voltage drops. Interference with other equipment/machines may occur in case of unfavourable mains system conditions.
Malfunctions are not to be expected for system impedances below 0.32 ohm.

Noise/Vibration Information

Sound emission values determined according to EN 60335-2-79.
Typically the A-weighted noise levels of the product are:
Sound pressure level
Sound power level
Uncertainty K
Wear hearing protection!
Vibration total values a
(triax vector sum) and uncertainty K determined according to
h
EN 60335-2-79:
Vibration emission value a
h
Uncertainty K

Mounting and Operation

Action
Delivery Scope
Handle Assembly
Filling up detergent tank
Connecting to the water supply
Cleaning the Filter
Connecting high pressure water supply
hose/nozzle
Adjust water pressure
Adjust water jet
Switching On and Off
Clean nozzle
Bosch Power Tools
kW
°C
l/min
MPa
MPa
l/min
MPa
N
kg
See serial number (rating plate) on pressure washer.
Starting
Figure
Page
For Your Safety
1
245
2
246
3
246
4
247
Your machine is double insulated for safety and requires no
earth connection. The operating voltage is 230 V AC, 50 Hz
5
247
(for non-EU countries 220 V, 240 V as applicable).
For increased electrical safety use a Residual Current Device
6
248
(RCD) with a tripping current of not more than 30 mA. Always
7
248
check your RCD every time you use it.
8
249
The supply cables must be inspected for signs of damage at
9
249
regular intervals and may only be used if in perfect condition.
10
250
GHP 5-14
3 600 J10 1..
2.4
50
8.3
14
15
8.3
1
22.98
Class F
IPX5
l
0.32
23.4
/I
3 600 ...
J 10 1..
dB(A)
84.5
dB(A)
dB
2
m/s
=4.91
m/s
2
=1.5
Warning! Switch off, remove plug from mains
before adjusting, cleaning or if cable is cut,
damaged or entangled.
1 609 92A 3ER | (12.7.17)
English | 15
GHP 6-14
3 600 J10 2..
2.6
50
10.5
14
15
10.5
1
32.24
Class F
IPX5
0.32
25.6
/I
J10 2..
82.5
92
90
=3
=3
=4.91
=1.5