GYS M1 AUTO Manual De Instrucciones página 9

Ocultar thumbs Ver también para M1 GYS AUTO:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
«MANUAL» MODE (FIG 5)
1-welding mode choice:
- Normal (2T): standard two-stage welding
- Delay: intermittent welding modes for an optimised
operating procedure.
- Spot:spotwelding with ajustable spot diameter
2- Wire speed settings: wire speed fitting potentiometer.
The speed varies from 1 to 15L/minute.
3- Spot/delay potentiometer fitting
4- Manual mode: In manual mode, the wire speed is
determinated by the user by adjusting the potentiometer
(2).
«MANUAL» MODE (FIG 5)
To set your device, proceed as follow:
- Choose the welding voltage using the 7 positions switch
Example: position 1 for 0,6mm metal sheets and position 7 for 4 mm metal sheets.
- Adjust the wire speed with the potentiometer(2).
Advice:
The wire speed adjustment is often determinated « with the noise »: the arc must be stable and have a low
crackling. If the speed is too low, the arc is not continuous. If the speed is too high, the arc crackles and the wire
pushes back the torch.
«SYNERGIC» MODE (FIG 5)
This function will set the wire speed automatically.
For this:
Position the wire speed potentiometer (2) in the middle of the« Optimal synergic » zone.
-Select:
-The wire type (5)
-The wire diameter (5) The power mode (7 position switch), to select the right position in accordance with the thic-
kness of the part to weld, please refer to the table (fig 6)
From this combination, they determines the optimal wire speed and the device is ready to weld. It is also possible
to adjust the wire speed if necessary by adjusting potentiometer (2) + or – manually. A memory of the last welding
configuration is done (wire diameter, wire type, mode).
GAS choice (only for steel welding) :
In synergic mode, it's determines the welding settings in accordance with the gas used. By default, in steel welding
the machine is set in « Argon + CO2 ».
To change the gas and set the machine in C02 mode or come back in Argon + CO2 mode, process as explained:
1-Press « Type » for 5 seconds until the keyboard switches off the release.
2-Within 5 seconds, choose the required setting with the key « choose mode ».
-Normal (2T) => Argon + CO2 (default setting)
-Delay => CO2 100%
3-The confirmation is done either by the « Type » key, or by waiting for 5 seconds.
4-Once confirmed, the machine reverts to the normal functioning mode but the modification is registered even when
the machines is switched off.
SPOT MODE (FIG 5)
This function allows spot welding. To adjust the length of each spot, use the potentiometer (3).
DELAY MODE (FIG 5)
Allows intermittent welding, the delay can be adjusted through the potentiometer (3).
This function allows welding very thin steel or aluminium metal sheet, limiting the risk of piercing and distortion
(especially for aluminium welding).
M1 - T1 & T3 GYS AUTO
5- Synergic mode: position the potentiometer (2) in the
middle of the «optimal synergic» zone. In this mode, the
device determines the optimal wire speed according to 3
parameters:
- Voltage
- Wire diameter
- The power mode.
It's possible to adjust the wire speed +/-.
In position Normal(2T), 2 modes are proposed to ease
the settings of the device: Manual or Synergic.
EN
13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

T1 gys autoT1 gys auto dvT3 gys autoT3 gys auto dv

Tabla de contenido