FAULT DIAGNOSIS BY REMOTE CONTROLLER
The temperature display sections indicate corresponding codes.
1.
When the ON TIMER CANCEL button or OFF TIMER CANCEL button is held down for
5 seconds, a "
ON TIMER CANCEL
2.
Press the ON TIMER CANCEL button or OFF TIMER CANCEL button repeatedly until a
continuous beep is produced.
The code indication changes as shown below, and notifi es with a long beep.
ERROR CODE
00
A1
A3
A5
A6
AH
C4
C5
C7
C9
E1
E3
E4
E5
E6
E7
E8
E9
EA
F3
F6
HO
H3
H6
H7
H8
1-EN-OM-GS02-0411(0)-Siesta.indd3 3
1-EN-OM-GS02-0411(0)-Siesta.indd3 3

FAULT DIAGNOSIS

00 00
" indication fl ashes on the temperature display section.
SWING
TURBO
QUIET
ON
CANCEL
NORMAL
INDOOR PCB ERROR
DRAIN PUMP ABNORMAL
ANTIFREEZE (COOLING)/HEAT EXCHANGER OVERHEAT (HEATING)
INDOOR FAN MOTOR ABNORMAL
ELECTRICAL AIR CLEANER ABNORMAL
INDOOR HEAT EXCHANGER (1) THERMISTOR SHORT/OPEN
INDOOR HEAT EXCHANGER (2) THERMISTOR SHORT/OPEN
LOUVER LIMIT SWITCH ERROR
INDOOR ROOM THERMISTOR SHORT/OPEN
OUTDOOR PCB ERROR
HIGH PRESSURE PROTECTION
LOW PRESSURE PROTECTION
COMPRESSOR MOTOR LOCK/COMPRESSOR OVERLOADED
COMPRESSOR START-UP ERROR
OUTDOOR DC FAN MOTOR LOCK
AC INPUT OVER CURRENT
EXV ERROR
4 WAY VALVE ERROR
DISCHARGE PIPE OVERHEAT
HEAT EXCHANGER OVERHEAT
COMPRESSOR SENSOR SYSTEM ERROR
HIGH PRESSURE SWITCH ERROR
COMPRESSOR FEEDBACK DETECTION ERROR
FAN MOTOR OVERLOADED/OVERCURRENT/SENSOR ABNORMAL
AC CURRENT SENSOR ERROR
(For Inverter only)
FAN
MODE
SLEEP
TIMER
OFF
CLOCK
CANCEL
OFF TIMER CANCEL
MEANING