Diode test
7
To test the diode, turn the rotary switch to
position „
".
Then connect the measuring contacts to
the diode. The measured value acquired
for the forward voltage appears on the
display. If „O.L." appears on the display
instead of a measured value, the diode
has either been tested in the reverse
direction or is faulty.
8
Current measurement DC/AC
To take a current measurement in the range
from 0 to 200 mA, turn the rotary switch to
position „mA" and press the „Mode" button
to set the voltage mode (AC, DC).
Disconnect the circuit before connecting the
meter. Then connect the measuring contacts
to the object to be tested. The measured value
acquired and the polarity appear on the display.
Disconnect the circuit again before
disconnecting the meter.
No currents above 200 mA may be measured in the μA/mA
!
range! Currents above this level trigger the automatic
fuse in the meter (fuse 250 mA/250 V quick blow,
Ø 5 mm x 20 mm).