When the pictogram
is displayed, you may start the cleaning program:
- Press the settings and maintenance key
- Ensure that the pictogram
- The pictogram
The cleaning cycle: environ 10 minutes
- Lift the cup tray (J).
- Insert the KRUPS cleaning tablet in the opening intended for this purpose (I).
- Fill the water reservoir up to its maximum level of 1.7L (2).
- Empty the coffee grounds collector and the drip tray (34, 35, 36).
- Place the 600 ml container under the coffee outlets and the steam nozzle (7).
- Press the START
- The pictogram
- The first phase of the cleaning cycle starts.
- At the end of this cycle, the pictogram
- Empty the container and the drip tray and put them back in place.
The rinse cycle: environ 3 minutes
- Press the START
- The pictogram
- At the end of this cycle, empty the container and drip tray (34, 35, 36).
- Put the drip tray back in place.
Le cycle de nettoyage est terminé, le menu de recette café apparait, vous pouvez de nouveau utiliser votre machine.
!
Important: if you turn off or unplug your machine during cleaning or in the event of a power failure, the cleaning
program will start again at the step under way during the incident. It will not be possible to postpone
this operation, this is compulsory in order to rinse the water circuit. In this case, a new cleaning tablet
may be necessary. Properly perform the entire cleaning program to eliminate any trace of cleaning
product harmful to health.
Descaling program: Approximately 20 minutes
Running your machine's descaling program ensures that it is operating properly and eliminates any limescale deposits
that may influence the taste of the coffee.
The frequency at which this program is run depends on the quality of water used and whether or not a Claris Aqua
Filter System filter cartridge is used. The harder your water, the greater the frequency of descaling.
!
Important: ensure that you disconnect the milk pot (37) and remove the Claris Aqua Filter System cartridge if it is
fitted before starting a descaling cycle.
To perform this descaling, you will need:
- 1 dose of KRUPS descaler
- 1 container (minimum 600 ml)
The cycle will link three phases:
- 1 cleaning phase
- 1st rinse phase
- 2nd rinse phase
When should this program be performed?
- Each quarter.
- When the appliance advises you by lighting up the pictogram
!
Important: You are not obliged to immediately perform the descaling program when the appliance requests it, but
you must perform it as soon as possible. If the descaling is postponed, the pictogram will remain
displayed so long as the operation has not been performed.
It is recommended to perform the descaling to eliminate any limescale deposits that may influence the
taste of coffee.
The descaling program is an intermittent cycle; do not place hands under the steam outlet.
30
is selected, otherwise use the navigation key
flashes.
.
stops flashing.
flashes.
.
stops flashing.
.
.
.