Duress Access Control; Terminating A Triggered Alarm - jablotron JA-103K Manual Del Usuario

Ocultar thumbs Ver también para JA-103K:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 70
To set the entire premises in which partial setting is enabled, hold down the button to set the control
panel for 2 seconds or press it twice. After the button is pressed once it shows continuous yellow light,
after it is pressed a second time it shows continuous red light.
If the system is partially set already – the function button shows a continuous yellow light – the entire
system can be fully set by authorization and pressing the yellow button for a longer time. Once the
button is pressed, the system will be fully set and the button turns red.
Partial setting can be confi gured in a way that authorization is not required.
In order to unset the control panel when it is partially set, press the yellow button. The control panel will
unset and the button turns green.

2.1.3.4. DURESS ACCESS CONTROL

Provides unsetting of the control panel in a special mode. The system seemingly unsets, however it
triggers a silent panic alarm, which is reported to selected users (including ARC).
Unsetting under duress is executed by adding 1 to the last number in a valid code. Contact your
service technician if you want to use this feature.
Example:
Valid code: 9999

2.1.3.5. TERMINATING A TRIGGERED ALARM

1. Authorize yourself using
the keypad (enter a code or hold
a tag up to the reader).
A triggered alarm in progress is indicated by the status indicator and the function button rapidly fl ashing
red. You need to authorize yourself using the keypad in order to terminate the alarm. The section
remains set, a rapidly fl ashing red function button indicates the alarm memory. Indication will continue
fl ashing even after the system has been unset.
WARNING: If the alarm memory indication was activated during your absence, always enter the
building with caution, search for the cause of the alarm in the event history and be very careful when
checking the premises or wait until the security agency arrives (provided your system is connected to
an Alarm Receiving Centre).
The alarm memory indication remains on until the system is set once again. Alternatively, it can be also
cancelled from the keypad menu: Main menu – Cancel warning indication. Indication of a triggered
tamper alarm can be terminated only by a Service technician and Administrator.
Note: When using the "Default" system profi le, it is possible to select a particular action by pressing a
function button fi rst and then confi rm it by authorization using the keypad.
Terminating an alarm using a remote control will also unset the corresponding section.
Code for unsetting under duress: 9990
2. Press the function
button
of the section in which the alarm has
been triggered.
3. Unsetting is fi nished
and sirens
are silenced. Rapidly alternately
fl ashing function buttons (green/red)
and the status indicators indicate the
alarm memory.
EN
37

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ja-107k100+

Tabla de contenido