SERVICE PROCEDURES
Continued
FAN
1
Remove motor, motor mount and fan (see
Motor, steps 1 through 8, page 8).
2. Clean fan using soft cloth moistened with
kerosene or solvent.
3. Dry fan thoroughly.
4. Replace fan on motor shaft. Make sure set-
screw is touching back of flat surface on motor
shaft (see Figure 8).
5. Place setscrew on flat of shaft. Tighten set-
screw firmly (40-50 inch-pounds [46.08-57.60
kilogram-centimeters]).
6. Place motor, motor mount and fan guard
into rear of heater shell (see Motor, steps 14
through 18, page 8).
Fan
Figure 8 - Fan, Motor Shaft and Setscrew
Location
Hub
Figure 9 - Fan Cross Section
111710-01B
Setscrew
Motor Shaft
Fan
Motor
Shaft
Setscrew
www.desatech.com