SATEL
13. Start the identification function in the control panel (see the control panel installer manual). How
the keypad will be identified depends on selected operating mode.
Address setting and operating mode selection
The keypad with factory default settings has address 0 and its operating mode is "partition keypad
with proximity card reader". If you wish to change its address or select another operating mode, follow
the procedure below.
1. Power off the keypad (if it is powered on).
2. Disconnect the green (DTA) and black (CLK) wires from the terminals of the control panel
expander bus.
3. Short the green and black wires.
4. Power on the keypad.
5. The
and
black wires).
6. Set the address or select the operating mode.
Address setting
1. Press in turn
2. The
LED will start flashing.
3. Use the numeric keys to enter a new address from the range of 0 to 31.
4. Press
.
5. The
and
mode (press
(DTA) and black (CLK) wires to the corresponding terminals of the control panel expander bus).
Operating mode selection
1. Press in turn
2. The
LED will start flashing.
3. Select the operating mode by pressing one of the keys:
- partition keypad with proximity card reader (INT-SCR),
- entry keypad (INT-ENT),
- partition keypad (INT-S/SK).
4. Press
.
5. The
and
and
in turn) or end the procedure (turn power off and connect the green (DTA) and black
(CLK) wires to the corresponding terminals of the control panel expander bus).
The declaration of conformity may be consulted at www.satel.eu/ce
LEDs will start flashing alternately (then, you can disconnect the green and
and
.
LEDs will start flashing alternately. You can proceed to select the operating
and
in turn) or end the procedure (turn power off and connect the green
and
.
LEDs will start flashing alternately. You can go on to set the address (press
INT-SCR