Installation Instructions
Motor Protection Circuit Breaker
(Cat 140M-C2E-...; 140M-C2N-...; 140M-C2T-...; 140M-D8E-...; 140M-D8N-...; 140M-D8T-...; 140M-D8V-...)
WARNING: To prevent electrical shock, disconnect from power source before installing or servicing. Install in suitable enclosure. Keep free from contaminants.
WARNUNG: Vor Installations- oder Servicearbeiten Stromversorgung unterbrechen, um Unfälle zu vermeiden. Die Geräte müssen in einem passenden Gehäuse eingebaut und
gegen Verschmutzung geschützt werden.
AVERTISSEMENT: Avant le montage et la mise en service, couper l'alimentation secteur afin d'éviter tout accident. Prévoir une mise en coffret ou armoire appropriée. Protéger le
produit contre les environnements agressifs.
AVVERTENZA: Per prevenire infortuni, togliere tensione prima dell'installazione o manutenzione. Installare in custodia indonea. Tenere lontano da contaminanti.
ADVERTENCIA: Desconectar la alimentación eléctrica antes de realizar el montaje y la puesta en servicio, con el objeto de evitar accidentes. Instalado en una caja o armario
apropiado. Proteger el producto de los ambientes agresivos.
ПРЕДУПРЕ
Ж
ДЕНИЕ: Для предотвращения удара электрическим током отключите питание перед монтажом или обслуживанием. Устанавливайте в соответствующий
корпус. Устанавливать в местах, защищённых от грязи и пыли.
IEC/EN 60947-2, -4-1
UL 60947-4-1
CAN/CSA-C22.2 No. 60947-4-1
GB 14048.2
L2
L1
L3
1
3
5
1, 3, 5
2
4
6
2, 4, 6
T1
T2
T3
2
1 x 1...6 mm
2
2 x 1...4 mm
2
2 x 1...6 mm
2 x No. 16...8 AWG
2
2 x 1...6 mm
2 x No. 16...10 AWG
9 mm
Use 75°C Cu wire only
2...2,5 Nm
18...22 lb-in
No. 3
Pozidriv No. 2
Short Circuit Ratings
USA/CND Manual Motor Controller and Self-Protected Combination Motor Controller
Group Motor
Cat. No.
Installation
480V
600V
Allen-Bradley
140M-C2E-A16...B16
65
140M-C2E-B25
65
65
140M-C2E-B40
140M-C2E-B63. . .C10
65
30
140M-C2E-C16
140M-C2E-C20
30
140M-C2E-C25
25
25
140M-C2E-C29. . .C32
140M-C2T-A16. . .B10
65
140M-C2T-B16
65
140M-C2T-B25
65
140M-C2T-B40
65
140M-C2T-C10
30
30
140M-C2T-C16
65
140M-C2N-A16. . .B16
65
140M-C2N-B25
-N45
-KBH2
-UX...
-UC...
-SN...
-WBE
Self-Protected Combination Motor Controller
Motor Disconnect
and Tap Conductor Protection in Group
Installation for Manual Motor Controller
Max. Short Circuit Current [kA]
480V
600V
480Y/277V
47
65
47
65
30
65
30
65
25
65
25
65
30
65
30
65
30
30
30
30
30
10
10
10
10
10
5
—
5
10
—
—
47
65
47
65
47
65
47
65
25
65
25
65
30
65
30
65
30
30
30
30
30
10
10
10
47
65
47
—
30
65
30
—
-TE1
-N45
-CA
Cat. No.
600Y/374V
Allen-Bradley
47
140M-D8E-B25...C16
30
140M-D8E-C20
25
140M-D8E-C25
—
140M-D8E-C29...32
—
140M-D8N-B25...C16
—
140M-D8N-C25
—
140M-D8N-C32
—
140M-D8T-C16
47
140M-D8T-C20
30
140M-D8V-B16...C20
25
140M-D8V-C25
—
140M-D8V-C29
—
140M-D8V-C32
—
—
—
-WTN
-W...N
-WTEN
-WSN
-ASA...
-ASAR...
-AFA...
-KRY1
-KN1
-AFA...
USA/CND Manual Motor Controller and Self-Protected Combination Motor Controller
Self-Protected Combination Motor Controller
Group Motor
Motor Disconnect
and Tap Conductor Protection in Group
Installation
Installation for Manual Motor Controller
Max. Short Circuit Current [kA]
480V
600V
480V
600V
65
30
65
30
65
30
65
30
30
30
30
30
30
30
30
18
65
30
65
30
30
30
30
30
30
30
30
18
65
30
65
30
30
30
30
30
65
—
65
—
30
—
30
—
30
—
30
—
30
—
30
—
480Y/277
600Y/347V
65
30
65
—
30
—
—
—
—
—
—
—
—
—
65
30
30
—
65
—
30
—
—
—
—
—