OPERATING ISSUE
The machine does not work.
The brush does not rotate.
The machine does not
clean evenly.
No detergent is delivered.
The suction motor does not
start.
The squeegee does not
clean or has poor suction.
PAGE 10 OF 36
TROUBLESHOOTING
CAUSES
The batteries need to be charged.
The brush button LED is off.
The brush motor thermal cutout has
tripped; the motor has overheated.
The batteries need to be charged.
The brush motor fuse has blown.
The brush or floor cleaning pad is
worn.
The detergent button LED is off.
The detergent tank is empty.
The brush motor is off.
The hose delivering the detergent
to the brush is blocked.
The detergent tap is dirty or faulty.
The in-line filter is dirty (left side from
operator's position near the wheel).
The fan button LED is off.
The vacuum motor fuse is blown.
The edge of the squeegee blades
in contact with the floor is worn.
The squeegee or hose is blocked or
damaged.
The float switch has tripped (dirty
water drum), is clogged by dirt or
broken.
The suction hose is blocked.
The suction hose is not connected
to the squeegee or is damaged.
Debris is trapped between the
squeegee blades.
RECOMMENDATIONS
Charge the batteries.
(See Instructions)
Press the brush button.
Turn off the unit. Let the machine
cool down for at least 45 minutes.
Charge the batteries.
Replace the brush motor fuse.
Replace the worn brush or floor
cleaning pad.
Press the detergent button.
Fill the detergent tank.
Turn on the motor by pressing the
brush button.
Unblock and open the detergent
tank tap.
Have the detergent tap cleaned or
replaced.
Clean the filter. Make sure to close
the detergent tap prior to cleaning.
Press the fan button.
Replace the vacuum motor fuse.
Replace the squeegee blades.
Unblock and repair the damage.
Empty the recovery tank or reset
the float switch.
Unblock the hose.
Connect or repair the hose.
Clean out debris from the
squeegee blades.
0521 IH-9424