5.5.2
Holes
5
5
5
5
Fig. 20:
Hole pattern
1 Hole 27
2 Hole 18
3 Hole 10
4 Hole 1
5 Shims
6 Guide block
i
Fit 1 shim (2 mm) at each drilling location.
i
Perform diagonal and vertical levelling until the
tolerance range is attained.
M
Nm
A
M6
4
M8
23
Fig. 21:
Guide block
Beissbarth GmbH
5
1
2
3
4
5
Product description | VAS 6430 | 27 | en
5.5.3
Floor preparation
i
The unit can only be properly erected on a smooth,
horizontal concrete floor with no cracks.
5.5.4
Fitting connectors
Fitting connectors
5
5
6
i
Always make use of a dust extractor when drilling.
Step
1
2
3
4
5
|
1 690 386 012
2013-09-24