CONTROL TYPE: Select the temperature control type. A PID device with default settings programmed is
recommended.
-
OPEN WINDOW DETECTION: Activates when open windows detected (On/Off).
-
INTELLIGENT START-UP: Adaptable start-up activation (On/Off).
-
COMPENSATION: Correction of room temperature (Values from -5ºC to 5ºC).
-
NOMINAL CHARGE: Ecombi Solar can operate with hourly discrimination tariffs of 8 or 14 off-peak hours. Set the
device for 8 or 14 hours according to the number of off-peak hours of your tariff.
3.5.3 Reset and default factory settings
You can reset the unit and restore factory setting configuration.

Default Values

Parameter
Sun: Comfort temperature
Moon: Economic temperature
Frost protection temperature
UP01: Initial % of storage charge
UP02: Starting time off peak period 1
UP03: Ending time off peak period 1
UP04: Starting time off peak period 2
UP05: Ending time off peak period 2
UP06: Charging days of the week
UP07: Ambient sensor Offset
UP08: Max. Balancing element – working period
UP09: Overtemperature protection
UP10: Temperature Unit
UP11: Open Window Detection Function
UP12: Adaptive Start Control
UP13: Kind of temperature control
UP14: Weekend Balancing Element restriction
Incorrect time settings, erroneous programming of the reduced rate time and too high temperature settings may result in a high cost
of your electricity bill.
3.6. Emitter Mode
This operation mode is used when it is necessary to heat the room temporarily and there is no need for storage heating. To set
this mode, turn off the unit by pressing the main switch on the back-side panel and keep pressed
on the unit by pressing the main switch until the message 19.0E is displayed on the display.
-
Emitter mode is a temporary operation mode. You cannot access from this mode to general setting menu,
operation mode menu or any other settings.
-
Use
and
balancing heating element if required in order to provide instantaneus heat to the room.
-
The unit will not charge within this mode.
To exit emitter mode and go back to the commom operation mode, just turn off and turn on the unit again by pressing the main
switch on the back-side panel.
to modify the set-point temperature for this operation mode. The unit will turn on the
8 hours setting
21ºC
18ºC
3ºC
100%
00:00
08:00
00:00
00:00
Charging 7 days of the
week.
0ºC
5 hours
2ºC
ºC
Off
Off
PID
On
24
14 hours setting
21ºC
18ºC
3ºC
100%
22:00
12:00
00:00
00:00
Charging 7 days of the
week.
0ºC
3 hours
2ºC
ºC
Off
Off
PID
N/A
at the same time you turn