Operating Procedures
& Safety Data Sheet
YOUR SAFETY IS OUR FIRST PRIORITY
e-NRG is ONLY suitable for use in liquid bioethanol fires. Do not use in
anything with a wick, or anything designed for other fuel types such as
gel, kerosine, gasoline, etc. Always follow recommended procedures
provided by the fireplace manufacturer.
e-NRG is ONLY to be used in compliance with these Operating Procedures
and the Operating Procedures of the bioethanol fireplace where you intend to
use this product.
Please refer to the Safety Data Sheet (SDS) for important Health and
Safety information.
WARNING: Fuel containers without flame arresters, if used improperly, can
result in the inflammation of the fuel within the container, which may cause
property damage, personal injury, or even death.
NEVER pour e-NRG over an open flame.
NEVER fill an appliance/burner directly from the e-NRG bottle,
risk of explosion.
INSTRUCTIONS FOR SAFE USE
This decanting procedure must be performed in a well ventilated space
away from any sources of ignition.
When using an EcoSmart Fire Burner:
If you are an owner of an authentic EcoSmart Fire, you would have
received a Jerry Can with an attached Safety Spout as part of the
standard operating accessories. An Adapter is available to connect the
Safety Spout to the e-NRG bottle which eliminates the need to decant
the fuel from the bottle into the Jerry Can.
1. Attach the Adapter to the Safety Spout.
2. Attach the Safety Spout with Adapter to the e-NRG bottle and ensure
it is securely fastened. You are ready to approach the burner (the
burner must be in an off/cold state).
Without the e-NRG Adapter the procedure below must be followed.
Manuals and videos are also available online:
www.ecosmartfire.com/about/fireplace-safety
When using in a bioethanol fireplace that does NOT have an
EcoSmart Fire Burner:
e-NRG must be decanted into an approved Jerry Can that is fitted with a
flame arrester following the instructions outlined below.
1. Remove the cap from your e-NRG bottle and the spout from the Jerry
Can.
2. In a safe location, away from any source of ignition, carefully decant
the fuel from the bottle into the Jerry Can through its opening, avoiding
spillage. If spillage occurs, clean thoroughly before proceeding.
3. Re-screw the cap tightly back onto the Jerry Can to contain fuel and
avoid accidental spillage. Test that it is closed securely before moving
away from your decanting area.
4. You are ready to approach the burner (the burner must be off and
in a cold state). Once the e-NRG bottle is empty, put the original lid
securely back onto the bottle for safe recycling.
QUESTIONS?
If you have any questions please visit www.e-nrg.com/safety, or if you
prefer to speak to a Customer Service Representative, please contact us.
+1 (888) 670 ENRG /
info@e-nrg.com
Safety Spout
Adaptor
1.
1.
3.
2.
2.
4.