Voltage And Circuit Protection; Grounding Instructions - Porter Cable CPF6025VP Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Voltage and Circuit Protection

Refer to the specification chart for voltage and circuit protection requirements of
your compressor. Use only a fuse or circuit breaker that is the same rating as the
branch circuit on which the air compressor is operated. If the compressor is
connected to a circuit protected by fuses, use only dual element time delay fuses.
Piping
compressed air. Regardless of its indicated pressure rating, plastic
pipe can burst from air pressure. Use only metal pipe for air
distribution lines.
If a pipe line is necessary, use pipe that is the same size as the air tank outlet.
Piping that is too small will restrict the flow of air. If piping is over 100 feet long, use
the next larger size. Bury underground lines below the frost line and avoid pockets
where condensation can gather and freeze. Apply pressure before underground
lines are covered to make sure all pipe joints are free of leaks.
A flexible coupling needs to be installed between the air discharge valve outlet and
main air distribution line to allow for vibration.

GROUNDING INSTRUCTIONS

circuit, grounding reduces the risk of shock by providing an escape
wire for the electric current. This air compressor must be properly
grounded.
If these grounding instructions are not completely understood, or if in doubt as to
whether the compressor is properly grounded, have the installation checked by a
qualified electrician. The air compressor is equipped with a cord having a
grounding wire with an appropriate grounding plug. The plug must be used with an
outlet that has been installed and grounded in accordance with all local codes and
ordinances. The outlet must have the same configuration as the plug. See Fig. 3.
DO NOT USE AN ADAPTER.
Inspect the plug and cord before each use. Do not
use if there are signs of damage.
electrical shock!
Do not modify the plug that has been provided. If it
does not fit the available outlet, the correct outlet
should be installed by a qualified electrician.
If repairing or replacing cord or plug, the grounding
wire must be kept separate from the current-carrying
wires. Never connect the grounding wire to a flat
blade plug terminal. The grounding wire has
insulation with an outer surface that is green - with or
without yellow stripes.
Additional Regulators and Controls
Since the air tank pressure is usually greater than that which is needed, a separate
regulator is usually employed to control the air pressure ahead of any individual air-
driven device.
Plastic or PVC pipe is not designed for use with
RISK OF ELECTRICAL SHOCK! In the event of a short
Improper grounding can result in
9-ENG