Translation of the original instructions
NB : In the event of a warning alarm, the machine does not work.
The machine is fitted with several protect ion systems against electrical overcharge and cooling faults.
The thermal protection mostly activates when heating stainless steel, aluminium and copper parts. To reactivate the machine,
simply wait for the cooling phase to end. For other protections, switch off the machine using the main switch and switch it
back on.
For fault alarms E-6 and E-7, check that there is no leak or an obstructed/broken hose, that the pump is not blocked or deacti-
vated and that there is enough cooling liquid in the tank.
If the problem appears to have been rectified, press the «inductor change» button twice (10) . The cooling circuit is performing
a purge cycle. It is ready to operate.
«ACCESSORY CHANGE» MODE
This mode is accessible only if the heating isn't activated (green button switched off).
1. Press the button (10), the pump stops and the LED (9) switches on.
2. Place the lance on its supports and put the cable on the ground (to prevent loss of cooling
liquid).
3. Unscrew the accessory by hand.
4. Change and screw the new inductor back on.
5. Press the button again (10).
The pump activates. For 5 seconds, the LEDs display a wait pattern.
If the flow is correct, the machine emits a double «BEEP» and the product is ready to operate.
Otherwise a fault is displayed (refer to the fault code table).
«PURGE» MODE
This mode is only available if the heat is not activated (green switch is off).
1. Push the button (10), the pump stops and the LED (9) lights up.
2. Position the torch on its support and place the cable on the floor (to avoid liquid spillage).
3. Unscrew the accessory by hand.
4. Push and hold the heat authorisation button (2) for 3 seconds until it lights up.
5. Place the torch button above a bucket with a capacity of 10 l minimum.
6. Push the torch button (11). The pump activates until the debit falls under 1 l/minute or for 2 minutes. The machine
displays the debit in decilitre per minute. To interrupt the pump during the cycle, push any button.
7. To empty the cooling circuit, use a blower to blow air (30PSI) at the end of the torch until you can hear the air
flowing or projections of liquid coming out of the tank.
8. To remove the remaining liquid from the bottom of the tank, unscrew the cap under the Powerduction using a
wrench (6x8). Once the tank is completely empty, screw the cap back on.
9. To top up the cooling liquid, refer to the installation instructions.
It is recommended to change the cooling liquid every year, otherwise you may damage the POWERDUCTION's lance.