1. Set the main switch (1) to ON.
The machine initialises in 2 seconds.
2. Press the heat authorisation button (2) as described on page 7. The indicator on button (2) and the lance support LED
(12) both switch on, indicating that the machine is ready to operate.
3. Position the inductor (13) flat on the workpiece (place the open part of the ferrite towards the workpiece).
4. Press the handle button (11) or the pneumatic pedal (14) to start the heating process ; if necessary, move the in-
ductor on the workpiece to heat a larger surface. The minimum power indicator light on the heating power indica-
tor (3) flashes at 10Hz to indicate that the power is active.
Do not heat the same area for too long (a few seconds are sufficient depending on the thickness) to
prevent the metal piece from melting.
It is possible to change the rated power during the heating.
The display provides a continuous update of the cooling liquid temperature.
- During the powering up phase, the pump and the cooling fan activate for a few seconds, to check that they are wor-
king properly.
- After the heating stops, let the cooling circuit operate to cool down the inductor, before switching off the machine.
- To modify the cooling liquid temperature unit, press and hold both settings buttons (4) until the desired unit is dis-
played (" -F-" = Farenheit / " -C- " = Celsius). Release the buttons, the change is saved and in effect.
The machine has been designed to minimise the risks due to electromagnetic fields. Some residual
risks persist and it is recommended to observe a security distance between the inductor and the ope-
rator's head/torso.
Heat on standby
For security reasons, the product deactivates the heat authorisation after 5 minutes of inactivity. The heat authorisation
button indicator and the lance support LED both switch off.
To reactivate the machine, press the heat authorisation button (2) or press and hold the lance button (11) for 1 second.
This feature is disabled after 20 minutes of inactivity.
It allows the user to stay in a working position without the need to reach for the machine.

WARNING LIGHTS

- The indicator 6 signals a machine/inductor fault.
- The indicator 7 signals a cooling circuit liquid flow fault.
- The indicator 8 signals a thermal protection of the power block or the excessive temperature of the cooling liquid.
Wait for the indicator to switch off and the machine is ready to operate.
The display 5 displays the fault code :
Fault code
E - 1
Heat authorisation button (2) is stuck.
E - 2
Lance button (11) is stuck.
E - 3
Keypad buttons are stuck (9) and (11).
E - 4*
Inductor intensity is too high.
E - 5*
Inductor intensity is too low.
E - 6
Flow is too high >6 l/min.
E - 7
Flow too low <4 l/min.
E - 8*
Internal fault.
E - 9
Voltage network fault.
E - 10
Power-up fault
E - 11
Regulation temperature measurement fault
The temperature does not change during
E - 12
heating
E - 13
Power relay fault.
- - -
Overvoltage fault.
*In the case of faults E-4, E-5 and E-8, restart the product after correcting the fault.
20
POWERDUCTION 160LG
Cause
In short-circuit or mechanically blocked.
In short-circuit or mechanically blocked.
In short-circuit or mechanically blocked.
Faulty lance or inductor in short circuit.
Inductor is not screwed properly or faulty lance.
Pierced hose or missing inductor.
Hose is pinched or obstructed, the pump does not operate.
Disconnected flat command cable.
The network voltage is too low under 165 V.
Pneumatic pedal active when powered up.
The temperature sensor is off or short-circuit.
Incorrectly positioned temperature sensor.
Connection cable unplugged.
Voltage above 300 V. sector.