Installation
Specifications
Power supply required. . . . . . . . . . . . . . . . . 115V or 230V, 60 HZ.
Liquid Temp. Range. . . . . . . . . . . . . . . . . . Less Than 120°F (50°C)
Suction Thread . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1/4" FNPT
Discharge Thread. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1" FNPT
Horsepower. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0
See Wiring Chart
Performance
Performance (in GPM) at Discharge Pressure (PSI) Shown
25
30
35
40
47
40
35
29
A
B
C
E
F
G
H
K
C
A
F
D
L
M
Figure 1 - Typical Layouts
Key:
A - Priming Plug
B - Gate Valve
C - Pump Discharge
D - Street El
E - Union
F - Priming Tee
45
50
Max PSI
17
-
49
684 0616
G - Pump Base
H -Solid, level foundation
J - Eccentric Reducer
K - Pipe Supports
L - Suction Piping
M - Foot Valve
Piping
Both suction and discharge piping should be
independently supported at a point near the pump to
avoid strains being placed on the pump. Start all piping
at pump to avoid strains left by a gap.
It is advisable to increase the size of both suction and
discharge piping at the pump if any appreciable run of
pipe is required. Never use a smaller suction pipe than
the suction connection on the pump. Use a pipe wrench
to hold the suction and discharge bosses of the pump
while making up the piping, to avoid putting excess
strain on the pump.
Suction Pipe
The suction pipe must be kept free from air leaks. Any
horizontal run of suction piping must have a gradual
upslope towards the pump. Avoid any fittings which may
cause an air trap. A foot valve should be installed to
prevent loss of pump prime.
Discharge Piping
A gate valve and union should be installed in the
discharge line. For removal of the pump for service, close
the gate valve, and disconnect the union.
Priming the Pump
Prime pump by filling both the pump and suction
line completely with water thru the priming tee.
Replace priming plug and start pump. If water is not
pumped immediately it is because all the air has not
been evacuated. Stop pump and reprime, following
instructions above. When used with vertical discharge,
the vent plug at the top should be loosened to evacuate
air which is trapped inside the volute. When volute is
completely filled with water, tighten vent plug.
Risk of explosion and scalding. NEVER run
pump against closed discharge. To do so can boil water
inside pump, causing hazardous pressure in unit, risk of
explosion and possibly scalding persons handling pump.
Risk of burns. NEVER run pump dry. Running
pump without water may cause pump to overheat,
damaging seal and possibly causing burns to persons
handling pump. Fill pump with water before starting.
Risk of burns. Motor normally operates
at high temperature and will be too hot to touch. It is
protected from heat damage during operation by an
automatic internal cutoff switch. Before handling pump
or motor, stop motor and allow it to cool for 20 minutes.
4