How to proceed:
 P
Remove the screws and remove the pump from the stand.
Remove the four screws and take off the pump casing.
Pull out the impeller unit and replace if necessary.
– Use a wide-blade screwdriver to carefully lever out the impeller unit if necessary.
Reassemble the unit in the reverse order.

Wear parts

• Impeller unit
• Bearing in the motor block
Storage/overwintering
The unit is not frost-proof and has to be removed and put into storage if minus temperatures are expected.
How to correctly store the unit:
• Thoroughly clean the unit, check it for damage and replace any damaged parts.
• Protect electrical connections from moisture and dirt.
• Store the pump submerged and in a frost-free environment.
• Protect open plug connections from moisture and dirt.
Repair
Repair is not possible in the following cases. The pump has to be replaced.
• If there is no replacement part approved by OASE for a defective component.
• If an electric cable permanently connected to the pump becomes damaged or is shortened.
Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.

Spare parts

The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare
parts.