Place the filter case into the
box (fig. 45).
- Fit the card funnel on to the
filter case (fig. 46).
- Cut off the corner of the poly
bag which contains the new
carbon granules (fig. 47).
- Pour in a complete bagful of
new carbon granules (fig. 48).
- Tap and shake the filter case
to settle the contents (fig. 49).
- Place a new foam screen over
the carbon granules (fig. 50).
- Refit the lid (fig. 51).
- Repeat this procedure for the other Carbon filter.
52
Resetting the Carbon filters replacement indicator
After replacing the Carbon filters, the Carbon filters
replacement indicator needs resetting:
- Switch the appliance on (fig. 52)
- Press and hold the Carbon filters reset button (P) during at
least 3 seconds (fig. 53).
The indicator light stays (or comes) on.
After some time it will go out to indicate that the indicator has
been reset.
Automatic overheating safety
device
To prevent damage and reduce
safety risks the overheating
safety device switches off the
fan motor if it becomes too hot.
-
50
yy
51
yy yy
yy yy yy yy
yy yy
yy
53
3 sec.
54
55
To indicate that the appliance is still in switched-on position
and connected to the mains, the indicator light will remain on.
If this happens:
- Switch the appliance off
(fig. 54).
(The indicator light goes out.)
- Remove the mains plug from the wall socket.
- Wait for the motor to cool down (approx. 15 minutes).
- Remove the front cover (fig. 55). Check that the filters are
not blocked and that nothing is obstructing the airflow.
- Check that the fan can rotate freely if moved by hand
(fig. 56).
- Close the appliance. Put the mains plug back into the wall
socket and switch on.
If the automatic overheating device is activated repeatedly, it is
advisable to take the appliance to your dealer for technical
inspection.
Fitting a different plug
This appliance is fitted with a BS 1363 13 Amp. plug.
Should you need to replace the plug, connect the wires as
follows:
Brown wire to the Live (L) terminal of the new plug.
Blue wire to the Neutral (N) terminal of the new plug.
Always fit the same value of fuse as that originally supplied
with your appliance.
Only use BS 1362 approved fuses.
As a guide only: Appliances under 700 W can have a 3 Amp.
fuse (red) and all others should have a 13 Amp. fuse (brown).
When disposing of an old plug (particularly the moulded type
which has been cut from the mains cord) always remove the
9
56
For U.K. only:

Publicidad

Tabla de contenido
loading