Changing the angle reference value
With button (2), it is possible to transfer angles elsewhere.
To do so, set the device to the desired slope and press
button (2). The display then changes to „0.0°", „REF"
flashes on the display and the required reference angle is
set. The slope can now be transferred to other objects.
Press button (2) again to deactivate the angle reference.
!
The angle reference is not deactivated
by switching off the device.
6
°C / °F / measured value
The ambient temperature is shown in °C and °F by briefly
pressing the CAL button (3). Press again to switch back to
the measured value.
7
HOLD
Press the HOLD button (5) to hold the current measured
value on the display.
8

Acoustic signal

The acoustic signal can be switched on or off with button
(6). When the angle of slope stands at 0°, 45°, 90° or the
most recently stored value, this is indicated by an acoustic
signal.
!
When working with a changed angle reference
value, the acoustic signal is activated on reaching
the new reference value (0°, 45°, 90° display).
9
Backlighting
The backlighting is switched ON/OFF by pressing
and holding button (6).

Auto Off function

In order to preserve the batteries, the measuring device
switches off automatically if it is left idle for 3 minutes.