Maintenance; Trouble Shooting - Fanimation Enigma FP2120 Serie Manual Del Propietário

Ocultar thumbs Ver también para Enigma FP2120 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Periodic cleaning of your new ceiling fan is the only
maintenance that is needed. When cleaning, use only a
soft brush or lint free cloth to avoid scratching the fi nish.
Abrasive and/or non-abrasive cleaning agents are not
required and should be avoided to prevent damage to
fi nish.
For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan.
Trouble
1. FAN WILL NOT START
2. FAN SOUNDS NOISY
3. FAN WOBBLES
EXCESSIVELY

Maintenance

Trouble Shooting

▲WARNING
Probable Cause
1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan, or loose
switch wire connections in the switch housing.
3. Dead battery in remote control.
1. Motor noise caused by solid state variable speed
control.
1. Setscrew in downrod support is loose.
2. Setscrew in downrod/hanger ball assembly is loose.
3. Hanger bracket and/or ceiling outlet box is not
securely fastened.
CAUTION
Do not use water when cleaning your ceiling fan. It could
damage the motor or the finish and create the possibility
of electrical shock.
1. Check main and branch circuit fuses or circuit
breakers.
2. Check line wire connections to fan and switch wire
connections in the switch housings.
CAUTION: Make sure main power is turned off !
3. Replace with fresh battery.
1. Some fan motors are sensitive to signals from
solid-state variable speed controls. Solid-state controls
are not recommended, choose an alternative control
method.
1. Tighten both setscrews securely in downrod support.
2. Tighten the setscrew in the downrod/hanger ball
assembly.
3. Tighten the hanger bracket screws to the outlet box,
and secure outlet box.
9
Suggested Remedy

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Enigma fp2120mg

Tabla de contenido