English
Error
At start-up, after
switch-off the white
LED, the LED flashes
8 times (red color)
(3 flashes/second).
Permanent flashing of
the LED (red color)
(6 flashes/second).
Permanent flashing of
the LED (red color)
(3 flashes/second).
10/2019
Description
Main configuration has
been restored from the
backup configuration.
The tool switched to default
setting.
All configurations have
been corrupted.
Tool blocked.
Validation / Action
User not affected by this issue during normal
work.
If the user was updating the configuration of
the tool with the Speed Setting Module, it is
recommended to check the speed of the tool.
This error appears if the main configuration has
been restored after corruption.
The tool can be used but only with the default
parameters.
Speed and counters may be affected.
It is recommended to check the parameters
with the Speed Setting Module. If the problem
persist when the battery is plugged in, it is
recommended to replace the electronic board.
This alarm appears if the memory chip is out of
order.
The electronic board must be replaced.
21 / 134
6159933730_27