4.2 SETTING THE CURRENT DAY AND TIME
- Press the
and
+
keys at the same time, insert the con-
nector in the valve (fig. 9, A) until the display will show the
day of the week, flashing.
+
- Press the
key and select the current day. Press
confirmconfermare
+
- Using the
and
, keys, set the current time. Press
confirm.
- Disconnect the connector from the valve (fig. 9, A).
4.3 INSTALLATION PROGRAM
To activate the water softener, perform the following opera-
tions:
• insert the power connector in the valve (fig. 9, A) and press
the
key until "SETTING AT WORK" appears on the
display.
• wait a few seconds, then slowly open the inlet tap (fig. 3,
D) first, and then slowly open the outlet tap (fig. 3, B)
The water softener will now run the installation program inde-
pendently, carrying out the following operations:
1. Backwash (B3)
2. First brine tank filling and quick wash (B7)
3. Resin suction and washing (B5)
4. Quick rinse and second brine tank filling (B7)
5. Service mode
The display will show the step that is currently being per-
formed and how many minutes are left until the end of the
installation.
At the end of the cycle, fill three-quarters of the brine tank
with salt (fig. 8); the water softener is now be ready for pro-
gramming.
It is possible to interrupt the installation program by pressing
and holding the
key for 5 seconds. The water softener will
go into service mode.

5) SETTING THE TIMER

When you set the timer, you can:
• set the days of the week when the resin regeneration will
be performed (for example Monday, Tuesday, etc), or set
an interval of days elapsing between a regeneration and
the next (for example every 3 days, or 12 days, etc)
• set the time when the regeneration will be performed
• set the water softener model
• set any possible modifications to the duration of regenera-
tions
• turn on the alarms alerting you that there is no salt in the
container.
Before you start with the settings, we advise you to take note
of the model (fig. 3, L).
ATTENTION: If no key is pressed for longer than 1 minute du-
ring the setting procedure, the display will go back to showing
the current time and day, storing the data inserted up to that
moment.
To go back to the setting step you had reached, you need to
repeat the programming from the beginning.
5.1 START
Insert the connector in the timer (fig. 9, A). The display will
show the time, the day, and the water softener model (for
example, if the water softener is an AL8, the writing -08- will
18
appear on the display).
to
OK
15:00
- 08 -
5.2 SETTING THE REGENERATION DAYS
Regeneration sequences can be set on a weekly schedule
or by setting an interval of days between a regeneration and
to
the next.
OK
ATTENTION: one setting will exclude the other. If you want to
to
set an interval of days between a regeneration and the next
OK
(paragraph 5.2.2) you must not select any regeneration day in
the weekly timetable (paragraph 5.2.1).
You will be able to modify the settings and switch from a
setting to the other whenever you want.
1) press
until the writing "PROGRAMMING: PRESS OK"
OK
appears.
2) press
again. The display will show the day, flashing
OK
5.2.1 SETTING THE REGENERATIONS ON A WEEKLY
SCHEDULE
Press
+
and an asterisk will appear (for example *Monday),
indicating that on that day the water softener will perform a
regeneration. If you press
ar, (Monday) cancelling the regeneration.
If you press the
Program the regenerations on the chosen days and then press
.
OK
If no asterisk is placed, the timer will allow you to set an in-
terval of days between a regeneration and the next (paragraph
5.2.2).
5.2.2 SETTING THE REGENERATIONS ON AN INTERVAL
OF DAYS
If you want to set an interval of days between a regeneration
and the next, do not place any asterisk and press
writing "REGENERATION EVERY 01 DAYS" will appear on
the display.
+
Using the
and
the regenerations.
For example: if you select 12, the water softener will perform
a regeneration every 12 days.
Values go from 00 (no regeneration) to 30 (one regeneration
every 30 days).
If you set 00, the water softener will never perform an auto-
matic regeneration, and you will need to do a manual one (see
paragraph 7.1).
After setting the number of days, press
5.3 SETTING THE REGENERATION TIME
After setting the days for the regeneration, the writing "START
REGENERAT. TIME - TIME:" will appear on the display.
1) set the regeneration time using the
press
to confirm.
OK
2) set the minutes using the
confirm.
5.4 CHOOSING THE PROGRAM FOR THE SOFTENER
The ALIA valve has three standard programs: 5, 8 and 12 –
one for each model.
When the display shows the writing "MODEL 5 YES=OK
NO=+", press
OK
model, or press the
writing "MODEL 8 YES=OK NO=+". Press
ENGLISH
MONDAY
+
again, the asterisk will disappe-
key, you can scroll down the days.
keys, set the number of days between
to confirm.
OK
+
or
+
or
keys and press
to confirm if the water softener is an AL5
+
key and the display will show the