6 Technical data

6
Technical data
A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is
available on the Daikin Business Portal (authentication required).
6.1

Piping diagram: Outdoor unit

7.0 CuT
7.0 CuT
7.0 CuT
7.0 CuT
7.0 CuT
7.0 CuT
Y1S
S1PH
k
9.5 CuT
a
Field piping (liquid: Ø6.4 mm flare connection)
b
Field piping (gas: Ø15.9 mm flare connection)
c
Stop valve (liquid)
d
Stop valve with service port (gas)
e
Filter
f
Muffler with filter
g
Capillary tube
h
Heat exchanger
i
Accumulator
j
Compressor accumulator
k
Muffler
M1C
Compressor
M1F
Fan
R1T
Thermistor (outdoor air)
R2T
Thermistor (heat exchanger)
R3T
Thermistor (compressor discharge)
S1PH
High pressure switch (automatic reset)
Y1E
Electronic expansion valve
Y1S
Solenoid valve (4‑way valve)(ON: cooling)
Heating
Cooling
Installation manual
12
h
R2T
4.0 CuT
4.0 CuT
4.0 CuT
M1F
12.7 CuT
12.7 CuT
R3T
12.7 CuT
j
i
M1C
R1T
g
g
6.4 CuT
6.4 CuT
g
f
Y1E
e
k
6.4 CuT
15.9 CuT
d
c
a
6.4 CuT
b
15.9 CuT
3D110394
ERGA04DAV37
Daikin Altherma 3 R
4P618926-1 – 2020.03