After selecting the Setup the following
settings can be customized.
- Language
- Charging voltage: CHARGE, EASY, SERVICE
Of pressing the respective button can be changed
the value. The charging voltage can range from
13,6V to 15,0V and the SERVICE-voltage can be
adjusted from 13,3V to 14,5V.
actual charging current, the charging voltage and the currently loaded ampere hour.
If instead an error message comes „No Battery connected", was no battery, a
completely discharged battery (the voltage of the battery is less than 3V) or
the battery cables are incorrectly (reverse polarity) connected.
The charging operation starts automatically as soon as a functioning battery
is connected.
The filling level of the battery indicator displays the approximate status of the battery
SETUP
EASY CHARGE
The charge level EASY-CHARGING is
used to charge lead-acid batteries
without any further charge settings are
necessary.
The battery is charged with a maximum
charge current 30 A and is suitable for
batteries between 30 Ah-150Ah. After
selecting EASY-CHARGING and when
the device is correctly connected to the
battery to be charged.
In the display appears additionally the