The charging stage CHARGE is for individualized charging of lead batteries
according to your battery size. After selecting the corresponding charge program
starts the charging.
All functions and display options are analogous to the EASY-CHARGE function.
In service mode, the charger provides a constant voltage and supplies the vehicle
electrical system if:
a.)
An inspection / repair / customer service / service on the vehicle must be
carried out.
In this position, the charger balances the power consumption of the vehicle
until it reaches its maximum rated capacity of (buffer mode).
b.)
The battery is disconnected. A loss of data in the on-board computer of the
vehicle is protected (sustained mode).
The board suitability is in all operating situations
guaranteed even during the re-/disconnect to the battery.
After disconnecting the battery starts the service operation and in the right part of
the display the battery-rated voltages and the current service charge rate will
appear.
interrupted any time by pressing the "STOP" button. The display returns to the basic
menu.
By pulling the plug from the wall outlet, the charger is turned off.
SERVICE OPERATION
After starting the service mode the
actual charging current and the
charging voltage is displayed.
If the actual charge current exceeds the
value of 55A, the device has reached its
capacity. If a higher power demand
expected, the device have to be
replaced with a more powerful device.
The service charge current course can
be read from the diagram.
The service operation can be
20