PROGRAMMING & INSTALLATION
INSTRUCTIONS
621D
RATINGS
• 125VAC 15A, 1875W General Purpose
• 125VAC 15A, 1875W Resistive
• 125VAC 1000W Tungsten
• 125VAC 8A Ballast
• 125VAC 1/2 HP
CARACTÉRISTIQUES
• 125 V c.a., 15 A, 1875 W usage général
• 125 V c.a., 15 A, 1875 W résistif
• 125 V c.a., 1000 W tungstène
• 125 V c.a., 8 A ballast
• 125 V c.a., 1/2 HP
CLASIFICACIONES
• 125 VCA 15 A, 1875 vatios para uso general
• 125 VCA 15 A, 1875 vatios resistivo
• 125 VCA 1000 vatios tungsteno
• 125 VCA 8A reactancia
• 125 VCA 1/2 HP
ONE YEAR LIMITED WARRANTY: If this product fails
because of a manufacturing defect within one year after
purchase, we will, at our option, either repair or replace
it at no charge. Our warranty does not cover damage
caused by accident, abuse or misuse. We assume no
further liability with respect to the sale or use of this
product. THIS WARRANTY IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING
THE WARRANTY OF MERCHANTABILITY. We make no
warranty with respect to the fitness of any goods for the
users particular application. This warranty gives you
specific legal rights, and you also may have other rights
which vary from state to state.
It is our intent to provide accurate and current
specification information. However, in the interest of
product improvement, TORK may alter the specifications
or constructional details without prior notice.
1. Plug the line cord into the 120VAC receptacle.
2. If the unit fails to respond within a few seconds, push the Reset button with an insulated tool.
3. To set the time, press and hold the
4. Press the h+ button to set the time in hours, and press the m+ button to set the time in minutes.
Press the Day button to set the day of the week. When you've set the correct time, release the
button. The unit is now keeping time.
5. Let the switch hang downward so moisture does not accumulate in the outlet. Install cord and
unit above ground level at least 1.5 M with the receptacle facing downward. Store indoors when not
in use. Suitable for outdoor locations. Not for water immersion or for use where directly exposed
to water.
1. If you want to move the clock forward one hour, press both the h+ and m+ buttons
simultaneously. The DST segment on the LCD will become visible, to demonstrate that you are in the
Daylight Saving Time Mode.
2. To go back to the standard time in the fall, press the h+ and m+ buttons simultaneously again.
The DST segment on the LCD will turn off.
The 621D memory can hold up to 9 programs. Each program consists of 2 events, an ON time and
an OFF time. The events can be set up to execute on a daily basis or on a combination of days.
1. Press the Timer button.The display shows:
2. As in setting the time, you use the h+ and m+ buttons to set the time of day that the event
will occur. Press the Day button to select the day(s) of the week in which you would like the
switch to turn ON. Along with individual day schedules, you can also set the switch to operate
on the following schedules, in order: MO-SU, MO, TU, WE, TH, FR, SA,SU, MO-FR, SA-SU, MO-SA,
MO+WE+FR, TU+TH+SA MO-WE, TH-SA, and then back to all days.
3. Press the Timer button again. This will store the program, and allow you to program the OFF
event. The display will show the "Timer 1 OFF" and " - - : - -". Set the OFF time using the h+, m+,
and Day buttons as in Step 2. Pressing the Timer button will store this event, and allow you to
program the second ON event. You can program up to nine (9) ON and OFF events this way.
To manually override the load status: When not setting the time, or programming a schedule, press
the
button: The load will change from ON to OFF, or from OFF to ON. The LCD display will
change to show the load is ON or OFF. The load will remain ON or OFF until the next scheduled
event.
Pressing
button will change the load from ON to OFF, or from OFF to ON. The LCD display will
change to show the load is ON or OFF. The load will remain ON or OFF until returned to the "A"
This feature allows you to change the actual switching times of previously programmed ON and OFF
events by up to 30 minutes before, or after their original programming. This gives your lights a
"lived-in" feel, providing added security.
1. To engage Random mode, press both the Day and h+ buttons simultaneously. The TIMER
segment on the LCD will blink, to demonstrate that you are in the Random Mode.
2. To go back to the regularly scheduled settings, press the Day and h+ buttons simultaneously
again. The TIMER segment on the LCD will no longer be displayed.
To review all programs:
1. Press the Timer
2. Each successive press of the Timer button will display the next program, alternating ON and OFF
schedules.
To Edit a program:
1. Use the Timer button until the LCD displays the schedule you want to edit.
2. Use the h+, m+ and Day buttons as earlier to change the desired time or day.
3. Press the Timer button to store the revised schedule and display the next.
To Delete a program:
There are two ways to prevent a program from happening; you can either erase it, or hide it. Use
the Timer button until the LCD displays the schedule you want to change.
(a) To erase a program:
Press the h+ button to advance the event time past 11PM will change the display to "--:--".
(b) To hide a program:
Press the
time. To reactivate the schedule, use the Timer button until the LCD displays the schedule section
that was hidden. Press the
FOR TECHNICAL SUPPORT: techsupport@nsiindustries.com 877.230.7874
PLEASE READ ALL INSTRUCTIONS FIRST
INSTALLATION INSTRUCTIONS
INSTALLATION
button.
TO ADJUST DAYLIGHT SAVING TIME (TWICE A YEAR)
PROGRAMMING
MANUAL OVERRIDE SWITCH
VACATION MODE
RANDOM ON/OFF TIMES
REVIEWING, EDITING OR DELETING PROGRAMS
button: the LCD will display "HI:dE". The unit will no longer switch the load at that
again. The earlier selected event time will reappear.
LI-916(D)