Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

INSTALLATION INSTRUCTIONS
WIRING FOR SS410 Series
1. Turn power off at the electrical panel.
INSTALLATION INSTRUCTIONS
2. Connect the timer red wire to low voltage supply positive (+). Connect the timer black wire to low voltage
SS410
supply negative (-). Connect the green wire to Ground. Connect blue (common) and grey (normally open) or
IN-WALL DIGITAL
orange (normally close) as required. Cap unused wires.
3. Mount the timer inside electrical box using 2 mounting screws provided.
INTERVAL TIMER
4. Turn power on at the electrical panel.
ONE YEAR LIMITED WARRANTY: If this
5. Timer dip switches are factory preset for 2 hour operation. Change dip switches and program only if custom
product fails because of a manufacturing
setting is desired. Follow SET-UP INSTRUCTIONS.
defect within one year after purchase,
we will, at our option, either repair or
6. Close timer cover and install wall plate. Settings are now tamper resistant.
replace it at no charge. Our warranty
7. Remove wall plate to open timer cover and change settings.
does not cover damage caused by
accident, abuse or misuse. We assume
no further liability with respect to the sale
or use of this product. THIS WARRANTY
IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING
24VAC
THE WARRANTY OF MERCHANTABILITY.
or
We make no warranty with respect to
24 VDC
the fitness of any goods for the users
particular application. This warranty
gives you specific legal rights, and you
also may have other rights which vary
from state to state.
It is our intent to provide accurate
and current specification information.
However, in the interest of product
RETROFITTING A SS410 TO EXISTING 3-WAY OR 4-WAY SWITCH
improvement, TORK may alter the
1. Turn power off at the electrical panel.
specifications or constructional details
without prior notice.
2. Connect the timer red wire to low voltage supply positive (+) and to "Traveler A". Connect timer yellow wire to
"Traveler B". Connect the timer black wire to low voltage supply negative (-). Connect the green wire to Ground.
Connect blue (common) and grey (normally open) or orange (normally close) as required. Cap unused wires.
3. Mount the timer inside electrical box using two mounting screws provided.
4a. (3-way switch wiring Figure 1): At switch #1 connect "Traveler A" to one side of a single pole switch. Connect
"Traveler B" to the other side of the single pole switch.
4b. (4-way switch wiring Figure 2): At switch #1, connect "Traveler A" to one side of a momentary switch.
Connect "Traveler B" to other side of momentary switch. At switch #2, connect "Traveler A" together and to one
side of momentary switch. Connect "Traveler B" together and to other side of momentary switch.
5. Turn power on at the electrical panel.
6. Timer dip switches are factory preset for 2 hour operation. Change dip switches and program only if custom
setting is desired. Follow SET-UP INSTRUCTIONS.
7. Close timer cover and install wall plate. Settings are now tamper resistant.
8. Remove wall plate to open timer cover and change settings.
Note: Maximum 100ft wire length from the 3-way (multi-way) switch to timer.
Figure 1
ring
Orange
SS410 Series Wiring
NC
Blue
Switch #1
C
Grey
NO
Red (+)
24VAC
or
Black (-)
24 VDC
Orange
SET FOR 4-WAY OPERATION
NC
Blue
Yellow
C
The SS410 timer is factory preset for 3-way wiring with a maintained wall switch.
Grey
Green
Optional 4-way (multi-way): Open timer door and press reset button. Unit will display 3-W representing 3-way.
NO
SS410 Series 4-Way Wiring
Press the TIMER button to change screen to 4-W. After 10 seconds the display will blink twice. Display will confirm
Use momentary switches at all additional location.
operating hertz (60 typical). Unit now ready to program. Momentary switches must be used as additional switch
Tork #LCS115M
positions in the 4-way (multi-way) setting. Refer to wiring diagrams.
Figure 2
Connect Traveler A wires together
Use momentary switches at all additional location.
Connect Traveler A wires together
Traveler A
Traveler A
Traveler A
Traveler B
Traveler B
Traveler B
Switch #1
Switch #2
Connect a wire inside the gang-box
Connect a wire inside the gang-box
LI-1001(A)
to join Traveler B to the switch
to join Traveler B to the switch
SS410 Series Wiring
Red (+)
Black (-)
Orange
NC
Blue
Yellow
Switch #1
C
Grey
Green
NO
SS410 Series 4-Way Wiring
Use momentary switches at all additional location.
Tork #LCS115M
Connect Traveler A wires together
Traveler A
Traveler B
Switch #1
Switch #2
Connect a wire inside the gang-box
to join Traveler B to the switch
SS410 Series 3-Way Wiring
24VAC or 24 VDC
Traveler A
Red (+)
SS410 Series 3-Way Wiring
Orange
Black (-)
Traveler B
24VAC or 24 VDC
Blue
Yellow
Grey
Green
Green
Traveler A
Red (+)
Black (-)
Traveler B
Switch #1
Yellow
Green
Green
24VCA or 24 VDC
SS410 Series 4-Way Wiring
Tork #LCS115M
24VCA or 24 VDC
Red (+)
Red (+)
Traveler A
Orange
Black (-)
NC
Orange
Traveler B
Black (-)
Blue
Yellow
C
Blue
Yellow
Grey
Grey
Switch #2
Green
Green
NO
Green
Green
SET-UP INSTRUCTIONS FOR THE SS400 SERIES
When powering up for the first time, allow 1 minute for unit to show OFF on screen. If the screen in blank
after 1 minute, press RESET button, see Figure 3.
Default Set 2 hours
The SS410 timer is factory preset to meet newer energy code override mandates. No adjustment is required.
This setting will provide a two hour maximum operating time before shut off. The scroll feature is active to
allow the user to change the operating time with the maximum time setting at two hours.
DIP SWITCHES
SS410 Series 3-Way Wiring
1
2
3
4
4 HOUR
2 HOUR
LIMIT
SCROLL
24VAC or 24 VDC
OFF
ON
OFF
ON
Traveler A
Red (+)
Close the timer door and unit is ready. One press of the bottom cover turns the load ON and load will stay
ON until a countdown to the preset off time. Pressing the bottom cover again will turn load OFF.
SS400 SERIES
Orange
Black (-)
Traveler B
DIP SWITCH SETTINGS
NC
SET FOR OTHER THAN FACTORY DEFAULT OPERATION
Blue
Yellow
C
Figure 3
Grey
Green
Green
NO
ON - SWITCH UP
OFF - SWITCH DOWN
24VCA or 24 VDC
TIMER BUTTON
Red (+)
RESET BUTTON
Traveler A
Orange
Traveler B
Black (-)
NC
Blue
Yellow
C
1. 4HR: Set ON for preset 4 hour maximum countdown when 2HR is set to OFF.
Grey
Green
Green
NO
Also used in custom time programming.
2. 2HR: Set ON for preset 2 hour maximum countdown when 4HR is set to OFF.
Also used in custom time programming.
SS400 SERIES
3. LIMIT: Used with programming sequence. Switch from ON to OFF to limit scroll to match custom time.
DIP SWITCH SETTINGS
4. SCROLL: Set ON allows timer to scroll to a shorter run time. Set OFF to disable. Also used in
programming sequence. Switch from ON to OFF to set a custom time. The time scrolls in steps:
FRENCH
5 minute steps from 5 minutes to 1 hour.
10 minute steps from 1 to 4 hours.
30 minute steps from 4 hours to 12 hours.
1 hour steps from 12 to 24 hours.
5. BEEPER: Set ON activates feature for beep warning every 15 seconds starting at 2
minutes before OFF. See Figure 4.
ON - INTERRUPTEUR ALLUMÉ
6. BLINK: Set ON activates feature for load flash 2 minutes before OFF. See Figure 4.
OFF - INTERRUPTEUR ÉTEINT
BOUTON TIMER (MINUTEUR)
NC
SET FOR 4 HOUR
C
Change the dip switch settings, as shown below, to provide four hour maximum operating time before shut
off as allowed by some energy codes. The scroll feature is active to allow the user to change the operating
NO
time with the maximum time setting at four hours.
Orange
DIP SWITCHES
NC
Blue
C
1
2
3
4
5
Grey
4 HOUR
2 HOUR
NO
LIMIT
SCROLL
BEEPER
OFF
ON
OFF
ON
OFF
SS400 SERIES
DIP SWITCH SETTINGS
ON
OFF
OFF
ON
OFF
SPANISH
NC
ON (ARRIBA)
C
OFF (APAGADO)
NO
BOTON DE TEMPORIZADOR
BOTON DE REINICIO
NSi Industries LLC • USA • www.nsiindustries.com
ACTIVATING WARNING FEATURES
The SS400 series provides for a warning 2 minutes before shutting load off. The optional audible warning
beeps every 15 seconds for the 2 minute warning period. The optional blink warning will turn off the load for
1 second at 2 minutes before shut off.
1
2
4 HOUR
2 HOUR
OFF
ON
5
6
OFF
ON
BEEPER
BLINK
To activate one or both, change the switch matching the feature to the ON position. An icon will confirm these
OFF
OFF
features are active. See Figure 4.
SET A CUSTOM TIME (SOMETHING OTHER THAN 2 OR 4 HOURS)
The SS400 series may be programed to a custom length of time for countdown. The time can range between
5 minutes and 24 hours. The scroll feature is active to allow the user to change the operating time up to the
Figure 4
custom time setting.
1
2
4 HOUR
2 HOUR
OFF
ON
ON
ON
"
"= Beeper
"
" = Blink
ON
ON
ON
ON
SET A CUSTOM TIME AND ALLOW SCROLL UP TO 24 HOURS.
The SS400 series may be programed to a custom length of time for countdown. The scroll feature is active to
allow the user to change the operating time up to the maximum time setting of 24 hours.
1
2
2 HOUR
4 HOUR
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OPERATIONS
6
Once set-up is complete, attach the supplied decorator-type wallplate to the unit. The bottom cover becomes
BLINK
the switch to control the timer operations. Press the bottom cover once. Timer goes to preset time, turns load
OFF
Factory Default
ON, and starts countdown interval to automatic OFF. Pressing the bottom cover again will turn load OFF. If
Settings
the SCROLL feature is active, press and hold the main bottom cover and timing will change. Release when the
OFF
Set DIP Switches as
desired time is shown.
shown
In the OFF mode, LCD screen scrolls timer interval message every 15 seconds (SEt - For - HH:MM - LOAD -
OFF). Example of 3 hour default message: SEt - For - 02:00 - LOAD - OFF.
FOR TECHNICAL SUPPORT: techsupport@nsiindustries.com 888.500.4598
DIP SWITCHES
3
4
5
6
LIMIT
SCROLL
BEEPER
BLINK
OFF
ON
OFF
OFF
Factory Default
Settings
OFF
ON
OFF
ON
Set BLINK to ON
DIP SWITCHES
3
4
5
6
LIMIT
SCROLL
BEEPER
BLINK
OFF
ON
OFF
OFF
Factory Default Setting
ON
ON
OFF
OFF
1. Set DIP SWITCHES as shown
2a. Press and release TIMER button
2b. Wait for screen to show count-
down.
2c. Press and hold TIMER button.
2d. Release button when desired time
shows
OFF
OFF
OFF
OFF
3. Set LIMIT and SCROLL switch to
OFF
OFF
ON
OFF
OFF
4. Set SCROLL switch to ON
DIP SWITCHES
3
4
5
6
SCROLL
LIMIT
BEEPER
BLINK
OFF
ON
OFF
OFF
Factory Default Setting
OFF
ON
OFF
OFF
1. Set DIP SWITCHES as shown
2a. Press and release TIMER button
2b. Wait for screen to show countdown.
2c. Press and hold TIMER button.
2d. Release button when desired time
shows
OFF
OFF
OFF
OFF
3. Set SCROLL switch to OFF
OFF
ON
OFF
OFF
4. Set SCROLL switch to ON
LI-1001(A)

Publicidad

loading

Resumen de contenidos para Tork SS410

  • Página 1 IN-WALL DIGITAL orange (normally close) as required. Cap unused wires. The SS410 timer is factory preset to meet newer energy code override mandates. No adjustment is required. 3. Mount the timer inside electrical box using 2 mounting screws provided. This setting will provide a two hour maximum operating time before shut off. The scroll feature is active to...
  • Página 3 LE MINUTEUR 3. Fixez la minuterie à l’intérieur de la boîte électrique à l’aide des deux vis de montage fournies. Les minuteries SS410 est préréglées à l’usine pour répondre aux exigences les plus récentes du code en matière BLINK 4 HOUR...
  • Página 4 3. Coloque y ajuste el temporizador adentro de la caja de conexiones eléctricas por medio de los dos tornillos de El temporizador SS410 se programa en fábrica a fin de cumplir con los nuevos mandatos de omisión de código OFF - INTERRUPTEUR ÉTEINT...