Installation Example - Piusi P 3.5 Serie Instalación Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83
Installation, use and maintenance
Installation
example
1
2
air
line
Fixing the
dispensing
system
14 /124
The diagram below provides an example of a possible
configuration for the installation of the "PIUSI P 3.5 - PIUSI P 5.5"
system. For support in designing a system, you need to consult
qualified personnel.
1
Bleed ball valve
¦
2
Filter
¦
Pressure regulator with pressure gauge - Set to max. 7 bar
3
¦
4
Lubricator
¦
5
Safety valve
¦
(mandatory)
6
Pump casing
¦
7
Max. pressure safety valve
¦
3
1
4
Fix the pump casing securely to the wall (ST version) using a suitable bracket,
or fix it to the lid of the drum (940 version), inserting it completely with pick-
up hose and tightening the fixing screws. Then connect the pump to the air
line, making sure that the components shown in the figure are present.
WARNING
¦
The air accessories must be fitted with suitable support brackets. The
pump unit fittings can be damaged by the weight of the accessories in the
line.
¦
Installations which fail to comply with diagram do not guarantee correct
operation of the pump.
¦
Air delivery pressures over 7 bar may damage the pump and system.
5
1
6
(mandatory)
7
user
M0352A EN