Technical Data; Troubleshooting - Gardena 5900/4 inox Instrucciones De Empleo

Ocultar thumbs Ver también para 5900/4 inox:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
(7)
1. Turn the filter
1/4 turn clockwise and remove it (bayonet lock).
(7)
2. Clean the filter
under running water.
3. Re-install the filter
(7)
in the opposite sequence.
The pump must not be operated without the filter.
To flush the pump:
After pumping chlorinated water, the pump must be flushed.
1. Pump lukewarm water (max. 35 °C), possibly adding a mild cleaning
agent (e. g. detergent) until the pumped water runs clear.
2. Remove residuals according to the waste disposal laws applicable in
your area.
5. STORAGE
To put into storage:
The pump is not frost-proof!
The product must be stored away from children.
1. Disconnect the pump from the mains.
2. Turn the pump upside down until no more water runs out.
3. Clean the pump (see 4. MAINTENANCE).
4. Store the pump in a dry, enclosed and frost-free place.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household waste.
It must be disposed of in line with local environmental regulations.
IMPORTANT!
v Dispose of the product through or via your municipal recycling
collection centre.

6. TROUBLESHOOTING

DANGER! Risk of injury!
Injury when the product starts accidentally.
v Disconnect the product from the mains before you trouble-
shoot the product.
Problem
Possible Cause
Pump is running,
Air cannot escape, because the
but doesn't deliver
pressure line is closed. (Pos-
sible kink in the pressure hose.)
Air in suction foot.
Filter is clogged.
Water level below minimum
water level when put into
operation.
When using the floating
suction, an air cushion
forms in the suction hose.
Pump does not start,
Thermal switch has turned the
or stops suddenly during
pump off because of overheat-
operation
ing.
Check valve is stuck.
Pumping without electricity.
RCD has triggered
(residual current).
Only with Art. 1771 / 1773:
Leakage warning is activated.
The maximum duration of the
leakage warning (low quantity
program 60 min. or 2 min.)
has been exceeded.
Leak on pressure side.
10
1768-20.960.01.indd 10
Problem
Pump is running,
but the delivery drops

7. TECHNICAL DATA

Submersible Pressure
Pump
Rated Power
Mains voltage
Mains frequency
Max. delivery capacity
Max. pressure /
max. delivery head
Max. submersion depth
Residual water level
Switch-on pressure
Min. submersion depth
for operation (approx.)
Power cable
Weight without cable
(approx.)
Fastening rope length
Max. media temperature
8. ACCESSORIES
GARDENA Floating suction
system
GARDENA 2- / 4-Way Valve
GARDENA Hose Clamp
GARDENA Hose Clamp
Remedy
GARDENA Pump Connection
v Open the pressure line
Set
(e. g. shut-off valve, delivery
units).
GARDENA Tap Connector
GARDENA Hose Connector
v Wait for about 60 seconds
until the pump has vented;
GARDENA Pump
if necessary, turn off and then
Connection Set
on again.
v Clean the filter
9. SERVICE / WARRANTY
(see 4. MAINTENANCE).
v Submerge the pump deeper.
Service:
Please contact the address on the back page.
v Remove the non-return valve
Warranty statement:
in front of the filter basket of
the extraction unit.
In the event of a warranty claim, no charge is levied to you for the services
provided.
v Clean the filter
GARDENA Manufacturing GmbH grants a warranty for all original
(see 4. MAINTENANCE).
Observe the max. media
GARDENA new products for two years from the date of original purchase
Temperature (35 °C).
from the retailer, provided that the devices have been for private use only.
This manufacturer's warranty does not apply to products acquired second
v Contact the GARDENA
hand. This warranty includes all significant defects of the product that can
Service.
be proved to be material or manufacturing faults. This war ranty is fulfilled
v Check fuses and electrical
by supplying a fully functional replacement product or by repairing the
plug connections.
faulty product sent to us free of charge; we reserve the right to choose
between these options. This service is subject to the following provisions:
v Disconnect the pump
and contact the GARDENA
• The product has been used for its intended purpose as per the
Service.
recommendations in the operating instructions.
v When using the low quantity
• Neither the purchaser nor a third party has attempted to open or
programme, shorten the
repair the product.
watering duration or interrupt
• Only Original GARDENA replacement parts and wear parts have been
for 5 minutes. Increase the
water consumption. Discon-
used for operation.
nect the mains plug.
• Presentation of the receipt.
v Eliminate any leak on the
Normal wear and tear of parts and components (such as blades, blade
pressure side.
fixing parts, turbines, light bulbs, V-belts / toothed belts, impellers, air
Possible Cause
Filter is clogged.
NOTE: For any other malfunctions please contact the GARDENA service depart-
ment. Repairs must only be done by GARDENA service departments or specialist
dealers approved by GARDENA.
Unit
Value
(Art. 1768)
W
900
V (AC)
230
Hz
50
l/h
5900
bar /
3,5 /
m
35
m
12
mm
15
bar
mm
100
m
15 (H07RN-F)
kg
7,5
m
15
°C
35
For dirt-free suction below the water surface.
For parallel connection for more than one hose
or connected devices.
For 25 mm (1") hoses via the connection nipple.
For 19 mm (3/4") hoses via the connection
nipple.
For 13 mm (1/2") hoses via the GARDENA
Connection System.
For 16 mm (5/8") hoses via the GARDENA
Connection System.
For 19 mm (3/4") hoses via the GARDENA
Connection System.
Remedy
v Clean the filter
(see 4. MAINTENANCE).
Value
Value
(Art. 1771)
(Art. 1773)
900
1100
230
230
50
50
5900
6100
3,5 /
4,7 /
35
47
12
17
15
15
2,2
2,9
100
100
15 (H07RN-F)
20 (H07RN-F)
7,5
8,1
15
20
35
35
Art. 1417
Art. 1210 / 1194
Art. 7192
Art. 7191
Art. 1750
Art. 18202
Art. 18216
Art. 1752
23.09.19 15:26

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

5900/4 inox automatic6100/5 inox automatic176817711773

Tabla de contenido